For this the gate arm will open slowely to the upper position. The motor lever will
press the end stop of this direction for some seconds. Then the motor lever will move
a few degrees back to it’s normal end position OPEN.
The first movement into the closed position will be done by a very low speed (appr.
3s to close). This is a safety device to check, if the parameters are set correctly.
All following signals will move the gate with the desired and adjusted speed.
Reset of break-away function (option)
If there is a break away contact mounted to the boom flange a reset pulse to the
push button S4 of the electronic plate (“reset after break away”) is required to
deactived the safety function which will hold open the gate arm.
This is a safety function to protect the service personal when after a break away of
the gate arm the arm is brought back to it’s normal position.
5. Controller for MIB10 gates
The controller unit has been specially designed for use with MIB 10 gates.
Most gate system configurations can be realized using the standard version of the
controller.
The position of the gate arm is continuously calculated by the controller. The
information comes from the hall-sensors inside of the motor. This replaces the limit
switch that is used in conventional barrier control systems. The combination of the
hall sensor and the controller unit guarantees the best possible control of the gate
arm movement.
Software modifications are normally included at the factory but they can also be
loaded into the controller unit at some later date. A special software tool for this
programming is necessary.
The gate is correctly wired at the factory and is supplied ready for immediate
connection.
Electrical connections that need to be made during installation are illustrated in Fig.
S0226.
Note!
If special functions are included, the connections will differ from those shown here. Please refer to the enclosed additional
wiring scheme.
S0226