background image

 

Telemotive MLTX Transmitter Instruction Manual 

1/13/2012 

Page 9 of 19 

  BRIDGE            

 

          TROLLEY                  

 

             HOIST      

HOIST

 

 
 
 

 
 

     

AUX 1 

 

 
 

AUX 2

 

AUX 3

 

AUX 4

 

E STOP

 

ON

 

-

 

OFF

 

 
 
BATTERY 

AUX 5

 

AUX 4

 

2.1: MLTX TRANSMITTER STANDARD CONFIGURATION AND OPERATION  

  WARNING 

BEFORE OPERATING THE TRANSMITTER FAMILIARIZE YOURSELF WITH ALL SAFETY 
INFORMATION IN THIS MANUAL, THE CORRESPONDING RECEIVER SYSTEM MANUAL, 
APPROPRIATE MANUAL SUPPLEMENTS AND ANY OTHER LOCAL, STATE, OR FEDERAL 
RULES OR REGULATIONS ALREADY IN EXISTENCE. FAILURE TO FOLLOW THIS WARNING 
COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1. 

Pre-engineered

 MLTX Control 

“MLTX-4L-3M-3S” has 4 Levers and 3 Speeds  

“MLTX-3L-3M-3S” has 3 Levers and 3 Speeds   

 

 

 

BRIDGE                         TROLLEY                            HOIST

AUX 1

AUX 2

AUX 3

AUX 4

E STOP

 

ON-OFF

 
BATTERY

 

       B

 

A          

 

BOTH

 

“MLTX-3L-3M-2S” has 3 Levers and 2 Speeds   
“MLTX-3L-5M-3S” has 3 Levers and 3 Speeds    
“MLTX-3L-3M-5S” has 3 Levers and 5 Speeds    

 

 

  BRIDGE            

 

         TROLLEY                  

 

           HOIST        

     AUX 

HOIST

 

AUX 1

 

AUX 2

 

AUX 3

 

AUX 4

 

E STOP

 

ON

 

-

 

OFF

 

 

BATTERY  

TANDEM

 

IND

 

 

AUX 1

AUX 2

AUX 3

AUX 4

E STOP

 

ON-OFF

BRIDGE       AUX TROLLEY     MAIN TROLLEY          HOIST         AUX HOIST

 
BATTERY 

TANDEM

 

IND.

 

TANDEM

 

IND.

 

“MLTX-5L-5M-3S” has 5 Levers and 3 Speeds    

Summary of Contents for Telemotive MLTX

Page 1: ...Telemotive Pre engineered MLTX Transmitter Remote Crane Controls May 2009 Part Number 178 00161 R2 TCMLTX 0 Copyright 2009 Magnetek Material Handling...

Page 2: ...624 7378 Magnetek Material Handling N49 W13650 Campbell Drive Menomonee Falls WI 53051 Telephone 800 288 8178 Website www magnetekmh com e mail info magnetekmh com Fax Numbers Main 800 298 3503 Sales...

Page 3: ...Y SELECTOR SWITCH 10 2 7 IND OR TANDEM ROTARY SELECTOR SWITCH 10 2 8 AUX 1 AUX 2 AUX 3 AND AUX 4 AUXILIARY SWITCHES 10 2 9 TIME OUT TIMER 11 2 10 TRANSMITTER SWITCH PROGRAMMING 11 2 10 1 SW3 POSITION...

Page 4: ...maintenance procedure practice etc which if not strictly observed could result in damage to or destruction of equipment or loss of functional effectiveness Cautions are highlighted as shown below CAU...

Page 5: ...AGE TO EQUIPMENT WARNING PLEASE FOLLOW YOUR LOCAL LOCKOUT TAGOUT PROCEDURE BEFORE MAINTAINING ANY REMOTE CONTROL EQUIPMENT ALWAYS REMOVE ALL ELECTRICAL POWER FROM THE CRANE OR MACHINERY BEFORE ATTEMPT...

Page 6: ...operator can move freely These aisles should be a minimum of three feet one meter wide or meet local regulations Crane operators should always position themselves for the best view of the crane they a...

Page 7: ...DEATH AND DAMAGE TO EQUIPMENT 1 10 BATTERY HANDLING Use only batteries approved by Telemotive for the specific product Do not dispose of a battery pack in fire it may explode Do not attempt to open t...

Page 8: ...approximately three hours While NiMH batteries give improved performance over NiCAD any rechargeable battery will give its best performance if the battery is fully discharged before recharging If you...

Page 9: ...XISTENCE FAILURE TO FOLLOW THIS WARNING COULD RESULT IN SERIOUS INJURY OR DEATH AND DAMAGE TO EQUIPMENT Figure 1 Pre engineered MLTX Control MLTX 4L 3M 3S has 4 Levers and 3 Speeds MLTX 3L 3M 3S has 3...

Page 10: ...the battery goes below a safe level the LED will not light Replace the battery immediately 2 5 LEVERS To activate motor functions press and hold the push button or lever that corresponds to the desire...

Page 11: ...ode 3 SW4 1 and 2 turned ON The 10K12 2 speed system will control up to 5 motors using the rotary selector switch This mode reconfigures two of the 10K12 auxiliary outputs Aux 1 and Aux 2 to be extern...

Page 12: ...eration so that the relay closes for the unselected function 2 15 SW4 POSITIONS 5 7 EXTENDED CRANE CONTROL STANDARD ALL OFF The Pre engineered MLTX transmitters are available with extended crane contr...

Page 13: ...on Manual 1 13 2012 Page 13 of 19 2 16 PRE ENGINEERED MLTX TRANSMITTER BOARD SETUP INFORMATION The Pre engineered MLTX CPU Board is shown in Figure 2 Refer to paragraphs 2 17 through 2 18 for setups F...

Page 14: ...r housing Switch SW2 B in the transmitter must match switch S4 B on the receiver microcomputer module and switch SW1 A in the transmitter must match switch S5 A on the microcomputer module 2 19 CHECK...

Page 15: ...pt any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance should...

Page 16: ...z 07 AK07 438 6 MHz 08 AK08 438 4 MHz 09 AK09 438 2 MHz 10 AK10 438 0 MHz 11 AK11 437 8 MHz 12 AK12 437 6 MHz 13 AK13 437 4 MHz 14 AK14 437 2 MHz 15 AK15 437 0 MHz 16 AK16 436 8 MHz 17 AK17 436 6 MHz...

Page 17: ...ys recommend that you have Magnetek service perform the repair If you need to refer to a parts list refer to your transmitters drawing that was included in the shipment of your transmitter For some pa...

Page 18: ...Telemotive MLTX Transmitter Instruction Manual 1 13 2012 Page 18 of 19 Figure 5 Older style enclosure board installation location example...

Page 19: ...Telemotive MLTX Transmitter Instruction Manual 1 13 2012 Page 19 of 19 Figure 6 Customer Replaceable Parts...

Reviews: