background image

SBP2 Pendant Pushbutton Stations Installation Instructions

June 2020

Page 8 of 26

1 Installing and Wiring the SBP2

®

 Pendant Pushbutton 

Station

1.1 Taking Precautions During Installation

Do not expose the unit to cold blasts of air that might cause 
condensation (for example, an air conditioning duct).

Do not expose the unit to cleaning solvents that will penetrate and 
damage the unit’s enclosure. 

Do not use cable that is split or cracked.

Whenever possible, assemble the pendant in a vertical position to avoid 
contaminates falling into the enclosure. 

Attach the pushbutton station to the strain-relief cable so that no tension 
forms on the pushbutton cable directly. 

DANGER

HIGH VOLTAGES ARE PRESENT IN THE CONTROL PANEL, JUNCTION 
BOXES, THE PENDANT’S ELECTRICAL COMPONENTS AND THE 
CONNECTION BETWEEN THESE COMPONENTS. 

Before installing, servicing or inspecting any electrical or mechanical 
components of this power equipment, disconnect power at the source and 
follow proper lockout/tagout procedures. 

DO NOT make or break electrical connections (for example, plugs and 
receptacles) without first disconnecting power at the source and following 
proper lockout/tagout procedures. 

REFER TO ANSI Z244.1 PERSONNEL PROTECTION – LOCKOUT/
TAGOUT OF ENERGY SOURCES. 

Only qualified personnel should install components, inspect and/or service 
this equipment. 

SBP2 Pendant Pushbutton Stations Installation Instructions

June 2020

Page 21 of 26

11 Assembly Drawing

 

Summary of Contents for SBP2

Page 1: ...SBP2 Pendant Pushbutton Stations Installation Instructions June 2020 SBP2 Pendant Pushbutton Stations Installation Instructions Part Number 005 1053 Rev 6 June 2020 Copyright 2020 Magnetek...

Page 2: ...SBP2 Pendant Pushbutton Stations Installation Instructions June 2020 Page 2 of 26 Page Intentionally Left Blank...

Page 3: ...l Cable 9 2 Wiring and Marking Information 10 3 Considering the Environment 11 4 Operating the SBP2 Pendant Pushbutton Station Safely 12 4 1 Conducting a Pre Operation Inspection 12 5 Typical Installa...

Page 4: ...78 Magnetek Material Handling N49 W13650 Campbell Drive Menomonee Falls WI 53051 Telephone Website E mail Fax Numbers Main Sales Service 800 288 8178 www columbusmckinnon com magnetek mhcustomerservic...

Page 5: ...ications This manual has been prepared by Magnetek to provide information and recommendations for the installation use operation and service of Magnetek s material handling products and systems Magnet...

Page 6: ...related equipment and systems DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury This signal word is to be limited to the most extre...

Page 7: ...hbutton Stations Installation Instructions June 2020 Page 7 of 26 NOTE A NOTE statement is used to notify people of installation operation programming or maintenance information that is important but...

Page 8: ...ension forms on the pushbutton cable directly DANGER HIGH VOLTAGES ARE PRESENT IN THE CONTROL PANEL JUNCTION BOXES THE PENDANT S ELECTRICAL COMPONENTS AND THE CONNECTION BETWEEN THESE COMPONENTS Befor...

Page 9: ...nd crimp style terminal when connecting the wiring terminal Do no solder the terminal or connect the bare wires directly 1 3 Disassembling Enclosure 1 Unscrew pendant cable grip nut 2 Remove the top c...

Page 10: ...are no bare cable conductor strands and that all conductors are insulated from each other 2 Make sure that the enclosure water seal is properly placed in the groove of the front cover 3 Reattach the b...

Page 11: ...prevent contamination of the switch contacts Call Magnetek at 800 288 8178 for replacement gaskets and labels SBP2 Pendant Pushbutton Stations Installation Instructions June 2020 Page 11 of 26 3 Cons...

Page 12: ...eration at a time When you are not using the pendant station hang the unit as shown on page 12 do not let it lay horizontally If a problem occurs during the operation of the pushbutton station stop op...

Page 13: ...e that the interlock mechanism is operating properly and that the buttons return to the OFF position when released Inspect the condition of the pendant on a regular basis dependent on duty cycle SBP2...

Page 14: ...tion Instructions June 2020 Page 15 of 26 6 Wiring and Repairing Use an approved round crimp style terminal when wiring the terminals Do not solder the terminal or connect the bare wires directly Repl...

Reviews: