background image

Wiring and Marking Information 

Pendants are supplied with a cord grip nut, compression ring and six 
cable grommets. See below for grommet sizing. 

Cable Diameter

Grommet #

.375”–.437”

00-4987

.437”–.562”

00-4980

.500”–.625”

00-4981

.562”–.687”

00-4982

.625”–.750”

00-4983

.687”–.812”

00-4984

Enclosure Reassembly 

  

WARNING 

When tightening enclosure screws, do not exceed 9 inch pounds of torque. 
Overtorquing enclosure screws may cause damage to the enclosure. 

1. Ensure that there are no bare cable conductor strands and that all
conductors are insulated from each other.
2. Make sure that the enclosure water seal is properly placed in the
groove of the front cover.
3. Reattach the back cover while carefully keeping the cable conductors
inside the enclosure wiring area. Tighten the enclosure assembly
screws.
4. Reinstall pendant top and top gasket. Tighten top screws.
5. Tighten pendant cable grip nut until cable is sealed and secure.
6. Install pendant strain relief split rings and strain relief cables if
applicable.

Removing the Button Cover and Nameplate Insert 

1. Using a small screwdriver, pry out the plastic nameplate insert.
2. Press one side of the nameplate insert into one side of the rubber
button cover, and pry the button cover side to wedge in the plastic
nameplate insert.
3. Remove the button cover (boot) only after the enclosure is
disassembled and the switch is removed from the enclosure. Then
press out the nylon retaining ring (using a small screwdriver), which
secures the button cover in the enclosure hole.
4. Snap the button cover into the enclosure hole from the front.

Summary of Contents for SBP2

Page 1: ...kee WI 53213 3615 Distributed by Ergonomic Partners Sales ErgonomicPartners com www ErgonomicPartners com Tel 314 884 8884 Part Number 005 1053 R5 2014 Magnetek SBP2 Pendant Pushbutton Stations Instal...

Page 2: ...ly the use of talc free cable for the wiring of all pendant stations Remove all contaminants from the housing and switch contact areas prior to sealing the enclosure and putting the pendant in service...

Page 3: ...Pilot Light Mounts in Standard Button Hole SBP2 PLX Y 120 Volt Yellow Pilot Light Mounts in Standard Button Hole SBP2 PLX Y Red Mushroom On Off Switch Push Pull SBP2 SMMH Blank to Cover Button Hole S...

Page 4: ...forked type terminal lug 5 Fasten each cable conductor to its respective terminal screw Refer to wiring and marking information on page 12 of this manual 6 Code the opposite ends of the cable conducto...

Page 5: ...keeping the cable conductors inside the enclosure wiring area Tighten the enclosure assembly screws 4 Reinstall pendant top and top gasket Tighten top screws 5 Tighten pendant cable grip nut until ca...

Page 6: ...which could cause an electrical shock or cause the crane and hoists to function improperly General Handling Do not place the pendant in a pool of water or immerse it in water Do not let the pendant sl...

Page 7: ...n immediately and contact the person in charge of maintenance Prior to inspection or repair of the pendant station disconnect power at source following lockout tagout procedures as outlined in ANSI Z2...