IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 40
4.2.4 Parameters
The parameters are organized by function group and determine how the VFD functions. These parameters are
programmed in the VFD’s software as measurable values or options—both of which will be referred to in this
manual as
settings
. While some of these parameters are associated with one setting, others are tied to a number of
possible settings.
By default, the IMPULSE
®
•G+ Mini is configured for a common crane system. If you find it necessary to change the
initial settings, it is recommended that you only allow qualified crane system technicians to program the VFD. This
can be accomplished by using the Password and Access Level features. For more information on these security
features,
4.2.5 Parameter Modes
All parameters are organized under four modes:
4.2.5.1
Operation Mode
VFD operation is enabled. VFD status LED lights.
4.2.5.2
Programming Mode
Parameter access levels, control method, motion, speed reference, and passwords are selected. Parameters are
set/read. Items to be set/read vary depending on the access level setting.
4.2.5.3
Auto-Tuning Mode
Motor parameters are automatically set by entering tuning data (motor nameplate values) when using V/f or OLV
control method.
4.2.5.4
Modified Parameters Mode
Only parameters that have been changed from the factory default settings are shown here. They can be set/read.
Summary of Contents for IMPULSE G+ Mini
Page 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Page 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Page 181: ......
Page 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...