Utility U0 Menu
124
AUTOTUNE SEL
ii
(AutoTune Selection)
The AutoTune feature allows for the drive to
automatically measure the stator resist (A5), D
Axis inductance (A5), and Q Axis
inductance(A5). The procedure itself may be
found in the Appendix on page ix.
UPLOAD/DL
(Upload/Download Parameters)
This enables the parameters to be transferred
from the operator to the drive or from the drive
to the operator. The software revision must be
the same in the drive as in the par file in the
operator.
To transfere parameters from the drive to the
operator select DRIVE TO OP XFR
To transfere parameters from the operator to
the drive select OP TO DRIVE XFR.
ii
Parameter accessibly through PM (U9) Operation
Power Meter
(Energy Monitor)
Within this menu a user can monitor the power
drawn by the motor and also regenerated from
the motor in a given period. Within this menu
the user can reset all counters also if required.
Note: It is assumed a regenerative device is
fitted in conjunction with the HPV900S2 when
monitoring REGEN PWR, if this is not the case
REGEN PWR informs you how much you
could save should you add a regenerative
device