10 Fault
INFORMATION
In the event of faults that cannot be remedied by taking the following measures:
►
Contact customer service (
|
Fault
Possible Causes
Actions
Reeling cable not
winding and
unwinding
The reel body rotates on its axle.
The feather key on the axle is missing or broken
►
Install the feather key
►
Replace the feather key
The application is not suitable for the
configuration of the device
►
Contact customer service
Faulty drive part(s)
►
Contact customer service
The reeling cable
winds and
unwinds
unevenly
The reel body and cable routing are not aligned
►
Align the cable routing
(
|
The hollow shaft is not perfectly horizontal or
right-angled to the unwinding/winding direction
►
Align the device
(
|
Reeling cable is twisted
►
Untwist the reeling cable
Faults of electric
current and data
transmission
Loose screws on the brush holders/slip rings
►
Check the screws.
►
Tighten screws if
necessary.
Very soiled brush holders/slip rings
►
Clean with contact spray
Worn carbon brushes
►
Replace the brush holders
A high moisture content in the stationary heater
cable enclosure is missing or faulty
►
Install stationary heater
►
Repair stationary heater
►
Retrofit ventilation
►
Replace the faulty seal
The device is exposed to unusual vibrations
►
Level uneven surface
►
Stop vibrations
Interruption of the
current and data
transmission
Flashover between phase and PE
►
Switch off device
►
Contact customer service
Electrical connection is interrupted
►
Check and establish
connection