(E)
13
RS97-1024NGZ Series
9. Specifi cations
9-1. Rotary Magnescale Specifi cations
Item
RS97-1024NGZ Series
Output signal
Compliant with SIEMENS DRIVE-CLiQ
Data format
DRIVE-CLiQ single-turn absolute format
Motor temperature detection
Not available
Detecting method
Magnetic (MR sensor)
Accuracy (at 20 °C)
±2.5 s
Resolution
23 bit
Count direction
Addition count when stator is fi xed and rotor is rotating clockwise
(Given along with the reference point output position on outside dimensions)
Response revolution
5000 min
-1
Operating temperature range
0 °C to +60 °C
Storage temperature range
–10 °C to +60 °C
Vibration resistance
150 m/s
2
(50 Hz to 2000 Hz)
Shock resistance
1000 m/s
2
(11 ms)
Degree of protection
IP65
Power supply voltage
DC 24 V (DC 17 - 30.8 V) (Compliant with SIEMENS DRIVE-CLiQ)
Current consumption
150 mA or less
Inrush current
4 A max. (when the power supply rising time is 10 ms)
Power supply protection
In the case of errors such as a reverse-connected power supply or over-voltage,
the internal fuse is cut to protect the power being supplied and wiring.
Dimensions
180 mm (inner diameter)
×
19 mm (thickness) (For details, see section 10,
“Outside Dimensions.”)
Cable length
1 m / 2 m / 3 m
(max. total length of 30 m using extension connection cables)
Output connector
SACC-M12MS-8Q SH by PHOENIX CONTACT Inc.
Compliant connector
SACC-M12FS-8Q SH by PHOENIX CONTACT Inc.
Moment of inertia
8.8
×
10
–3
kg
•
m
2
or less
Mass
3.5 kg or less (rotor: 0.6 kg, stator: 2.8 kg)
The information here is subject to change without notice.
Summary of Contents for RS97-1024NGZ Series
Page 3: ...RS97 1024NGZ Series J 1...
Page 4: ...RS97 1024NGZ Series 2 J...
Page 6: ...ii J RS97 1024NGZ Series...
Page 9: ...J 3 RS97 1024NGZ Series 1 6 2006 42 EC...
Page 10: ...4 J RS97 1024NGZ Series 2 MR LSI SIEMENS SIEMENS DRIVE CLiQ...
Page 11: ...J 5 RS97 1024NGZ Series 3 S N...
Page 12: ...6 J RS97 1024NGZ Series 4 4 1 SIEMENS DRIVE CLiQ cw CW 4 2 7...
Page 13: ...J 7 RS97 1024NGZ Series 5 SIEMENS DRIVE CLiQ 7 2 DRIVE CLiQ...
Page 17: ...J 11 RS97 1024NGZ Series 7 2 SIEMENS DRIVE CLiQ SINUMERIK 4 4SP2 SINAMICS 4 4SP1 SIEMENS...
Page 18: ...12 J RS97 1024NGZ Series 8 6 3...
Page 22: ...16 J RS97 1024NGZ Series 9 5 6 16 9 6 20 9 6 18 1 250 m 2 1...
Page 24: ...18 J RS97 1024NGZ Series...
Page 28: ...ii E RS97 1024NGZ Series...
Page 46: ...18 E RS97 1024NGZ Series...
Page 50: ...ii G RS97 1024NGZ Series...
Page 69: ...RS97 1024NGZ Series 1...