MIX- COUNT

STOP

VALUE:

0.00

COUNT:

0

B

F:

0

 

MIX-COUNT

 means mix-counting mode

   

RUN/STOP 

is the sign showing machine’s running or stop status. 

B

 is the sign of Batch Function is ON.

 

VALUE

 is for total Amount. 

COUNT 

is for total Quantity, 

F

 shows the 

quantity of foreign/fake coins. 

 

·

Press START/STOP key

the machine will enter into Total Amount & 

Quantity Display Mode interface:

   

MIX- COUNT

RUN

VALUE:

0.00

COUNT:

0

B

F:

0

 

At the same time, Motor will begin to run to get the machine work. 

When  coin  sorting  is  finished,  it  will  display  the  sorting  result  of 

genuine and foreign coins on the above interface. The foreign coins 

will be rejected into the right-most Rejected Coin Drawer.   

   

    After  the  machine  stops  running,  press  LIST  key  to  check 

Separate Channel Amount & Quantity Display Mode, shown as follows: 

(Press

 

  key to turn to choose different channel)

 

VALUE

COUNT

AMOUNT

2.00

50

100.00

0.50
0.01

50

90

25.00

0.90

 

VALUE: refers to the denomination   

    COUNT: refers to the quantity for each denomination 

AMOUNT: refers the amount for each denomination   

Summary of Contents for 211

Page 1: ...1 1 POCKETS COIN SORTER MAGNER 211 Operation Manual...

Page 2: ...ENTS 1 Introduction 3 2 Specifications 3 3 Function 4 4 Diagram 4 5 Socket board 5 6 Key Panel 6 7 Main Display Modes 7 8 Operating Procedures 7 9 Function Settings 10 10 Trouble Shooting 14 11 Precau...

Page 3: ...and sort coins of programmed denominations during which process the foreign coins will be sorted into Rejected Coin Drawer Our MAGNER 211 can be connected with printer external display or computer th...

Page 4: ...oins It also has a reject box for accepting the suspected coins The channel is listed as below Channel 1 Reject box By different setting the user can sort the desired coins into specific channel in th...

Page 5: ...Operation Manual V1 3 Page 5 of 16 5 Socket board Power switch Power socket RS232 for communication with PC PS2 reserved interface for external display USB for software upgrading LAN reserved socket f...

Page 6: ...ESC Return to MENU or clear rejected coin records 5 CLR Clear counting records or clear error codes Select different Channels or select different Menu Setting can also control Batch function ON OFF c...

Page 7: ...100 00 0 50 0 01 50 90 25 00 0 90 8 Operating Procedures Turn on the machine the machine will enter into self test mode and show following interface MODEL MAGNER 211 VERSION MainBoard V1 0 DispBoard...

Page 8: ...00 COUNT 0 B F 0 At the same time Motor will begin to run to get the machine work When coin sorting is finished it will display the sorting result of genuine and foreign coins on the above interface...

Page 9: ...s with the same denomination will go to pocket 1 the other coins will go to reject pocket Data Clear Under main modes interface press CLR key to clear all counted data Under main modes interface press...

Page 10: ...he BATCH value through the numeric key 0 9 the upper limit is 9999 Press CLRkey you can clear the BATCH setting NOTES The above steps are used for setting the BATCH number If you need to set the BATCH...

Page 11: ...press CLR to clear the message otherwise other key functions are not workable 2 VALUE VALUE SET VALUE CHANNEL 1 2 00 Under VALUE interface press key to switch the channel Under one channel press SET...

Page 12: ...ill enter into SYSTEM SET submenu press or key to make the cursor up and down And then press SET key to enter different setting interface 1 TIME DATE 2013 08 29 TIME 05 44 32 Under this interface if y...

Page 13: ...OINT ON Under this interface please press or key to turn ON OFF this function After setting press ESC key to return to main menu interface 4 PRINT PRINT0 ON 9600 BAUD Under this interface please press...

Page 14: ...GNET 3 are reserved in software and user does not need to set it 4 TOTAL TOTAL 0000017331 This interface shows a memory record of all counted coin quantity You can enter the 1017 view or press the ESC...

Page 15: ...solved please press CLR key to enter into main interface If the problem can not be solved please contact your local distributor for solution Notes If there are any foreign things get jammed on the rai...

Page 16: ...a day Clean the disc and hopper at least once a day with a brush If the machine needs maintenance or spare parts please contact the local supplier 13 Accessories 1 Power Cable 1pc 2 Nylon Brush 1pc 3...

Reviews: