1-13-2
R4NTI
Parameter
Tray open
Tray close
V*: Voltage
T*: Event timer
V0: 2.40 V
T1: 0.050 s
V1: 4.25 V
T2: 2.000 s
V2: 2.00 V
T3: 0.008 s
V3: 2.36 V
T4: 0.006 s
V4: 4.26 V
T5: 0.066 s
T6: 1.500 s
T7: 0.800 s
T8: 0.005 s
SLED
INNER-SW
close
open
Tray insertion direction
Tray ejection direction
T4
T2
T5
V0
V2
V1
T3
T1
SLED
INNER-SW
close
open
Tray insertion direction
Tray ejection direction
V3
V4
T6
T7
T8
Summary of Contents for ZC352MW8A
Page 1: ...SERVICE MANUAL DVD RECORDER ZC352MW8A...
Page 27: ...1 10 4 AV 2 4 Schematic Diagram E7H50SCAV2...
Page 28: ...1 10 5 E7H50SCAV3 AV 3 4 Schematic Diagram...
Page 29: ...1 10 6 E7H50SCAV4 AV 4 4 Schematic Diagram...
Page 31: ...1 10 8 SW Schematic Diagram E7H50SCSW...
Page 37: ...1 10 14 DTV Module 1 2 Schematic Diagram E7H50SCDTV1...
Page 38: ...1 10 15 DTV Module 2 2 Schematic Diagram E7H50SCDTV2...
Page 39: ...1 10 16 AV CBA Top View BE7H50F01013A...
Page 43: ...1 10 20 BE7H50F01013C SW CBA Top View SW CBA Bottom View...
Page 48: ...1 13 3 R4NTI Push close 0 08 V 0 02 s Push Close detection Threshold level...