To prevent injury to the user or other people and property damage, the following instructions 
must be followed. Incorrect operation may cause harm or damage. The seriousness is 
classified by the warning symbols below.

Safety Precautions

This symbol indicates the possibility of death or serious injury.

Definition of symbols used in this manual are as shown below.

!

!

WARNING

Always do this.

Never do this.

!

CAUTION

This symbol indicates the possibility of injury or damage to property.

Plug in power plug 

properly.

Do not modify power cord

length or share the outlet

with other appliances. 

Always ensure effective

grounding.

Unplug the unit if strange

sounds, smell, or smoke

comes from it.

Keep firearms away.

Ventilate room before operating air

conditioner if there is a gas leakage from

another appliance.

   Otherwise, this may cause

   electric shock or fire due to

   excess heat generation.

  This may cause electric shock or 

  fire due to heat generation.

  Incorrect grounding may cause 

  electric shock.

  This may cause fire and electric

  shock.

  This may cause fire.

  This may cause explosion, fire and, burns.

  This may cause electric shock or

 fire  due to heat generation.

  This may cause electric shock.

  This may cause failure of machine

  or electric shock.

  This may cause fire and electric 

  shock.

  This may cause fire and electric 

  shock.

  This may cause electric shock or fire.

  If the power cord is damaged, it 

  must be replaced by the manufac-

  turer or an authorised service 

  centre or a similarly qualified per-

  son in order to avoid a hazard.

  This could be harmful to your health.

  Incorrect installation may cause 

  fire and electric shock.

  This may cause electric shock.

   This may cause an explosion or fire.

  This may cause failure and electric shock.

Do not operate or stop the

unit by inserting or pulling 

out the power plug.

Do not operate with wet

hands or in damp 

environment.

Do not allow water to run

into electric parts.

Do not use the socket if it is

loose or damaged.

Do not use the power cord

close to heating appliances.

Do not damage or use an 

unspecified power cord.

Do not point airflow at 

room occupants directly.

Always install circuit

breaker and a dedicated

power circuit.

Do not open the unit

during operation.

Do not use the power cord near 

flammable gas or combustibles, such

as gasoline, benzene, thinner, etc.

Do not disassemble or modify unit.

!

!

!

!

!

WARNING

!

2

!

!!

    

Summary of Contents for W-08CR

Page 1: ...Before using this product please read the instructions carefully and keep for future reference MODEL W 08CR W 10CR W 12CR For any service needs call 1 855 368 8606 OWNER S MANUAL...

Page 2: ...dren should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in o...

Page 3: ...ion fire and burns This may cause electric shock or fire due to heat generation This may cause electric shock This may cause failure of machine or electric shock This may cause fire and electric shock...

Page 4: ...roduct or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the...

Page 5: ...that the power cord is damaged it cannot be repaired it must be replaced with a cord from the Product Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power cord wi...

Page 6: ...ODE SLEEP MODE CLEAN AIR MODE only on some models SET FAN SPEED TURNS UNIT ON OR OFF UNIT CONTROL Temp Temp Timer Timer On Off Sleep Check Filter Timer Auto Cool Dry Fan Low Auto Med High Clean Air Fa...

Page 7: ...NUED TO SELECT THE OPERATING MODE Press the MODE button Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off DO THIS To select mode press the Mode button Each time you...

Page 8: ...EATURE Press SLEEP button DO THIS In this mode the selected temperature will increase by one degree 30 minutes after the mode is selected The temperature will then increase by another one degree after...

Page 9: ...tton again to show the TIMER OFF Press or hold the UP or DOWN button to change the then at 1 1 hour increments up to 24 hours T he control w ill will count down the time remaining until start The sele...

Page 10: ...in your control that you should become familiar with The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on too abruptly This prevents overheating of the compr...

Page 11: ...fins on front and rear coils on the unit For 10000Btu h models only Tool Needed Phillips Screwdriver A Remove the air conditioner from the carton and place on a flat surface B Remove top rail from th...

Page 12: ...1 B Slide the free end section of the panel directly into the cabinet as shown in Fig 2 Slide the panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on th...

Page 13: ...els out against the window frame Fig 5 3 Place the frame lock between the frame extensions and the window sill as shown Fig 6 Drive 3 4 19mm or 1 locking screws through the frame lock and into the sil...

Page 14: ...ickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 10 Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between windows an...

Page 15: ...e replacing Or instead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Clea...

Page 16: ...ent may be touching the cold coil located behind the air filter Straighten the tube away from the coil The temperature may need to be set lower for the air conditioner to activate The compressor may h...

Page 17: ...d the unit initially Water dripping INDOORS when the unit is on COOL The air conditioner may have been improperly installed Tilt the air conditioner slightly outward to allow water to drain out Refer...

Page 18: ...rgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Switching Sound Droplets of water hitting condenser during normal operation may ca...

Page 19: ...ange without prior notice for product improvement Consult with the sales agency or manufacturer for details MAGNAVOX and SMART VERY SMART are registered trademarks of Koninklijke Philips N V and are u...