1-3-1
DVDN_ISP
IMPORTANT SAFETY PRECAUTIONS
Product Safety Notice
Some electrical and mechanical parts have special
safety-related characteristics which are often not
evident from visual inspection, nor can the protection
they give necessarily be obtained by replacing them
with components rated for higher voltage, wattage,
etc. Parts that have special safety characteristics are
identified by a
#
on schematics and in parts lists. Use
of a substitute replacement that does not have the
same safety characteristics as the recommended
replacement part might create shock, fire, and/or other
hazards. The Product’s Safety is under review
continuously and new instructions are issued
whenever appropriate. Prior to shipment from the
factory, our products are carefully inspected to confirm
with the recognized product safety and electrical
codes of the countries in which they are to be sold.
However, in order to maintain such compliance, it is
equally important to implement the following
precautions when a set is being serviced.
Precautions during Servicing
A.
Parts identified by the
#
symbol are critical for
safety. Replace only with part number specified.
B.
In addition to safety, other parts and assemblies
are specified for conformance with regulations
applying to spurious radiation. These must also be
replaced only with specified replacements.
Examples: RF converters, RF cables, noise
blocking capacitors, and noise blocking filters, etc.
C.
Use specified internal wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
D.
Use specified insulating materials for hazardous
live parts. Note especially:
1) Insulation tape
2) PVC tubing
3) Spacers
4) Insulators for transistors
E.
When replacing AC primary side components
(transformers, power cord, etc.), wrap ends of
wires securely about the terminals before
soldering.
F.
Observe that the wires do not contact heat
producing parts (heat sinks, oxide metal film
resistors, fusible resistors, etc.).
G.
Check that replaced wires do not contact sharp
edges or pointed parts.
H.
When a power cord has been replaced, check that
5 - 6 kg of force in any direction will not loosen it.
I.
Also check areas surrounding repaired locations.
J.
Be careful that foreign objects (screws, solder
droplets, etc.) do not remain inside the set.
K.
Crimp type wire connector
The power transformer uses crimp type
connectors which connect the power cord and the
primary side of the transformer. When replacing
the transformer, follow these steps carefully and
precisely to prevent shock hazards.
Replacement procedure
1) Remove the old connector by cutting the wires
at a point close to the connector.
Important:
Do not re-use a connector.
(Discard it.)
2) Strip about 15 mm of the insulation from the
ends of the wires. If the wires are stranded,
twist the strands to avoid frayed conductors.
3) Align the lengths of the wires to be connected.
Insert the wires fully into the connector.
4) Use a crimping tool to crimp the metal sleeve at
its center. Be sure to crimp fully to the complete
closure of the tool.
L.
When connecting or disconnecting the internal
connectors, first, disconnect the AC plug from the
AC outlet.
Summary of Contents for sylvania mwd2205
Page 16: ...1 6 3 H9801DC Fig D5 S 7 S 7 S 7 S 8 8 VCR Chassis Unit...
Page 41: ...1 12 10 H9802SCM8 Main 8 8 Schematic Diagram VCR Section DVC865F...
Page 63: ...1 18 2 H9801PEX Packing S2 S2 S2 S2 S1 Unit A14 S3 X1 X4 X20 X5 X2 X3...
Page 71: ...DVC840F MWD2205 DVC865F H9801UD H98K0UD H9802UD 2005 01 28...