PRODUCT SPECIFICATIONS

Model

Y-6

Y-7

Y-8

Waveform

AC

AC / HWDC

DC

Leg Span / Pole Spacing

2.0-11.0 in / 5.1-27.9 cm

Leg / Pole Contact Size

1.00 x 1.00 in / 25.4 x 25.4 mm

Cord Length

12 ft / 3.7 m

6 ft / 1.8 m

Duty Cycle

25%, maximum on time 90 sec

Lift Strength 

(4-6 in / 100-150

mm spacing)

> 10 lb / 4.5 kg

AC: > 10 lb / 4.5 kg

HWDC: > 50 lb / 22.7 kg 

50 lb / 22.7 kg

Magnetic Field

2.5 kA/m at 6 in / 152 mm spacing

9.8 kA/m at 6 in / 

152 mm spacing

Dimensions

7.5 x 2.0 x 10 in / 190 x 

51 x 254 mm

7.5 x 2.0 x 12 in / 190 x 

51 x 305 mm

7.5 x 2.0 x 10 in / 190 x 

51 x 254 mm

Weight

8.0 lb / 3.6 kg

8.3 lb / 3.8 kg

Yoke: 8.0 lb / 3.6 kg

Battery: 5.2 lb / 2.4 kg

Ingress Protection

(IEC 60529)

IP 54

Grounding

Complies with IEC 61010-1 grounding requirements

Electrical

115 VAC, 60 Hz, 6.0 A max

230 VAC, 50/60 Hz, 2.7 A max

6 VDC, 4 A max

Battery Capacity

N/A

6 VDC, 12 A-hr

Battery Charger

N/A

NA CEC: 115 V, 60 Hz,

1.25A max

Global: 100-240 V,

50/60 Hz, 0.2A max

Environmental

32-120°F / 0-49°C, up to 100% RH non-condensing,

up to 16,300 ft / 5,000 m altitude

Regulatory

Designed for Mains +/- 10%, Overvoltage Category II, Wet 

locations, Pollution Degree 2 environment

OPERATION

1. 

Y-8 Model Only: Charge battery before use.

2. 

Connect yoke to power supply / battery pack.

3. 

Select AC or DC operating mode using switch on back of yoke.  

 

 

WARNING: Do not operate selector switch while yoke is energized.

4. 

Position yoke legs at right angles to the direction of suspected discontinuities. Adjust legs 

as needed for best contact with surface.

5. 

Depress trigger to energize yoke. Apply magnetic particles to area between legs.

a. 

If using dry powder, blow off excess while yoke is energized to reveal indications.

b. 

If using fluorescent particles, view surface with UV-A in darkened environment to 

reveal indications.

6. 

Evaluate indications for size, shape, and relevant location.

7. 

Reposition yoke legs at 90-degrees to previous position and repeat steps 4-5 to reveal 

indications in all directions.

8. 

Y-6 and Y-7 Models Only: Demagnetize by energizing yoke then slowly withdrawing it from 
the surface, up to 18 in / 45 cm distance. NOTE: Use AC mode for demagnetization.

ACCESSORIES

Part Number

Description

624115

Calibrated Test Weight, 10 Lb

169799

Pie Field Gage

008M004

Magnetic Flux Indicators, set of 5

2480

Field Indicator Gauge, 10 Gauss

MAINTENANCE

• 

Use mild soap and a damp cloth to clean the yoke housing.

• 

Do not spray yoke housing or immerse any part of yoke in liquid.

• 

Legs may be detached at the joints for cleaning.

• 

Use a rust-preventative spray (LPS-2 or equivalent) on legs for lubrication.

Battery Charging

• 

Recharge battery after every 8-10 hours of use or if stored for extended time.

• 

Extreme discharge of battery will reduce battery life.

• 

Connect battery to charger before plugging charger into line power.

• 

Typical charging time is approximately 1.25 hours per 1 hour of use.

• 

Typical use over 8-10 hour shift would require 10-12 hours to recharge.

SERVICE

WARNING

Disconnect coil from line power before any disassembly or service.

CAUTION

To assure product safety and reliability, repairs should be performed 

by Magnaflux Authorized Service Center using original parts.

WARNING

If the AC/DC Conversion Assembly or the switch is replaced, 

gasketing must be inspected for integrity and replaced as needed. 

Failure to do so may allow liquid intrusion during use, which can result 

in electrical shock hazard and permanent damage to the yoke.