4
Y-6, Y-7, Y-8 Yoke
Operating Manual
English
3
English
Y-6, Y-7, Y-8 Yoke
Operating Manual
PRODUCT SPECIFICATIONS
Model
Y-6
Y-7
Y-8
Waveform
AC
AC / HWDC
DC
Leg Span / Pole Spacing
2.0-11.0 in / 5.1-27.9 cm
Leg / Pole Contact Size
1.00 x 1.00 in / 25.4 x 25.4 mm
Cord Length
12 ft / 3.7 m
6 ft / 1.8 m
Duty Cycle
25%, maximum on time 90 sec
Lift Strength
(4-6 in / 100-150
mm spacing)
> 10 lb / 4.5 kg
AC: > 10 lb / 4.5 kg
HWDC: > 50 lb / 22.7 kg
50 lb / 22.7 kg
Magnetic Field
2.5 kA/m at 6 in / 152 mm spacing
9.8 kA/m at 6 in /
152 mm spacing
Dimensions
7.5 x 2.0 x 10 in / 190 x
51 x 254 mm
7.5 x 2.0 x 12 in / 190 x
51 x 305 mm
7.5 x 2.0 x 10 in / 190 x
51 x 254 mm
Weight
8.0 lb / 3.6 kg
8.3 lb / 3.8 kg
Yoke: 8.0 lb / 3.6 kg
Battery: 5.2 lb / 2.4 kg
Ingress Protection
(IEC 60529)
IP 54
Grounding
Complies with IEC 61010-1 grounding requirements
Electrical
115 VAC, 60 Hz, 6.0 A max
230 VAC, 50/60 Hz, 2.7 A max
6 VDC, 4 A max
Battery Capacity
N/A
6 VDC, 12 A-hr
Battery Charger
N/A
NA CEC: 115 V, 60 Hz,
1.25A max
Global: 100-240 V,
50/60 Hz, 0.2A max
Environmental
32-120°F / 0-49°C, up to 100% RH non-condensing,
up to 16,300 ft / 5,000 m altitude
Regulatory
Designed for Mains +/- 10%, Overvoltage Category II, Wet
locations, Pollution Degree 2 environment
OPERATION
1.
Y-8 Model Only: Charge battery before use.
2.
Connect yoke to power supply / battery pack.
3.
Select AC or DC operating mode using switch on back of yoke.
WARNING: Do not operate selector switch while yoke is energized.
4.
Position yoke legs at right angles to the direction of suspected discontinuities. Adjust legs
as needed for best contact with surface.
5.
Depress trigger to energize yoke. Apply magnetic particles to area between legs.
a.
If using dry powder, blow off excess while yoke is energized to reveal indications.
b.
If using fluorescent particles, view surface with UV-A in darkened environment to
reveal indications.
6.
Evaluate indications for size, shape, and relevant location.
7.
Reposition yoke legs at 90-degrees to previous position and repeat steps 4-5 to reveal
indications in all directions.
8.
Y-6 and Y-7 Models Only: Demagnetize by energizing yoke then slowly withdrawing it from
the surface, up to 18 in / 45 cm distance. NOTE: Use AC mode for demagnetization.
ACCESSORIES
Part Number
Description
624115
Calibrated Test Weight, 10 Lb
169799
Pie Field Gage
008M004
Magnetic Flux Indicators, set of 5
2480
Field Indicator Gauge, 10 Gauss
MAINTENANCE
•
Use mild soap and a damp cloth to clean the yoke housing.
•
Do not spray yoke housing or immerse any part of yoke in liquid.
•
Legs may be detached at the joints for cleaning.
•
Use a rust-preventative spray (LPS-2 or equivalent) on legs for lubrication.
Battery Charging
•
Recharge battery after every 8-10 hours of use or if stored for extended time.
•
Extreme discharge of battery will reduce battery life.
•
Connect battery to charger before plugging charger into line power.
•
Typical charging time is approximately 1.25 hours per 1 hour of use.
•
Typical use over 8-10 hour shift would require 10-12 hours to recharge.
SERVICE
WARNING
Disconnect coil from line power before any disassembly or service.
CAUTION
To assure product safety and reliability, repairs should be performed
by Magnaflux Authorized Service Center using original parts.
WARNING
If the AC/DC Conversion Assembly or the switch is replaced,
gasketing must be inspected for integrity and replaced as needed.
Failure to do so may allow liquid intrusion during use, which can result
in electrical shock hazard and permanent damage to the yoke.