3
English
Y-6, Y-7, Y-8 Yoke
Operating Manual
PRODUCT SPECIFICATIONS
Model
Y-6
Y-7
Y-8
Waveform
AC
AC / DC
DC
Leg Span / Pole Spacing
2.0-11.0 in / 5.1-27.9 cm
Leg / Pole Contact Size
1.00 x 1.00 in / 25.4 x 25.4 mm
Cord Length
12 ft / 3.7 m
6 ft / 1.8 m
Duty Cycle
25%, maximum on time 90 sec
Lift Strength
(4-6 in / 100-150
mm spacing)
> 10 lb / 4.5 kg
AC: > 10 lb / 4.5 kg
DC: > 50 lb / 22.7 kg
50 lb / 22.7 kg
Magnetic Field
2.5 kA/m at 6 in / 152 mm spacing
9.8 kA/m at 6 in /
152 mm spacing
Dimensions
7.5 x 2.0 x 10 in / 190 x
51 x 254 mm
7.5 x 2.0 x 12 in / 190 x
51 x 305 mm
7.5 x 2.0 x 10 in / 190 x
51 x 254 mm
Weight
8.0 lb / 3.6 kg
8.3 lb / 3.8 kg
Yoke: 8.0 lb / 3.6 kg
Battery: 5.2 lb / 2.4 kg
Ingress Protection
(IEC 60529)
IP 54
Grounding
Complies with IEC 61010-1 grounding requirements
Electrical
115 VAC, 60 Hz, 6.0 A max
230 VAC, 50/60 Hz, 2.7 A max
6 DC, 4 A max
Battery Capacity
N/A
6 DC, 12 A-hr
Battery Charger
N/A
NA CEC: 115 V, 60 Hz,
1.25A max
Global: 100-240 V,
50/60 Hz, 0.2A max
Environmental
32-120°F / 0-49°C, up to 100% RH non-condensing,
up to 16,300 ft / 5,000 m altitude
Regulatory
Designed for Mains +/- 10%, Overvoltage Category II, Wet
locations, Pollution Degree 2 environment
OPERATION
1.
Y-8 Model Only: Charge battery before use.
2.
Connect yoke to power supply / battery pack.
3.
Select AC or DC operating mode using switch on back of yoke.
WARNING: Do not operate selector switch while yoke is energized.
4.
Position yoke legs at right angles to the direction of suspected discontinuities. Adjust legs
as needed for best contact with surface.
5.
Depress trigger to energize yoke. Apply magnetic particles to area between legs.
a.
If using dry powder, blow off excess while yoke is energized to reveal indications.
b.
If using fluorescent particles, view surface with UV-A in darkened environment to
reveal indications.
6.
Evaluate indications for size, shape, and relevant location.
7.
Reposition yoke legs at 90-degrees to previous position and repeat steps 4-5 to reveal
indications in all directions.
8.
Y-6 and Y-7 Models Only: Demagnetize by energizing yoke then slowly withdrawing it from
the surface, up to 18 in / 45 cm distance. NOTE: Use AC mode for demagnetization.