17
www.magmaweld.com
USER MANUAL | KULLANIM KILAVUZU
EN
RD 650 MW
Setting Pots
Set welding voltage and wire feeder speed also. Changing valves under submodules.
1-2
3-4
5
6
7
8
11
Digital Display
Numerical value of the selected welding parameter shows the current and voltage value during
welding process and shows wire speed and set voltage during idle state.
Sub Menu
To specify welding parameter times,
(P1)
0.0 / 10.0 sec. Pre gas time
(P4)
0.0 / 5.0 sec. Final ramp down time
(P2)
0.0 / 10.0 sec. Post gas time
(P5)
1 / 10 min. Cooling time
(P3)
0 0 / 10 O sec. Burn back time
(P6)
On/Of (1/0) to change the state of soft start on or off
Free Wire Button
To take the wire out at the constant speed.
Choice Button For Trigger Mode
To choose either 2 or 4 mode position.
Led
(9)
is on when selected 2. position
Led
(10)
is on when selected 4. position
Free Gas Button
Free gas output
Thermic Failure Led
Turns on of over temperature state.
3
1
5
6
7
9
10
8
4
2
11
3.1 User Interface