Magmaweld MONOSTICK 200 PFC User Manual Download Page 3

2

MONOSTICK 200i PFC

IDENTIFYING SAFETY INFORMATION

Ÿ

Ÿ

Ÿ

These symbols are being used to identify potential risks.
When seen a safety symbol in the manual, it must be understood that there is an injury risk and following
instructions must be read carefully to avoid potential risks.
While welding, keep the third persons and especially the children away from the work area.

UNDERSTANDING THE SAFETY WARNINGS

Read carefully the manual and the labels and the safety warnings on the machine.

Make sure that the warning labels positioned on your machine are in good order. Renew the damaged and
the missing labels.
Learn to operate the machine and how to make the controls properly.
Operate your machine in convenient work areas. Improper modifications affect the safety of your machine
negatively and shorten its lifetime.

Ÿ

Ÿ

Ÿ

SAFETY RULES

ELECTRICAL SHOCK C

FATAL

AN BE

Installation procedure must comply with national electricity standards and other relevant regulations
and ensure that installation is performed by qualified persons.

Ÿ

Ÿ

Ÿ

Ÿ

Wear dry insulating gloves

and body protection.

Do not touch electrode with bare hand. Do not wear wet or damaged gloves and
body protection.
Do not touch live electrical parts
Never touch electrode while in contact with working surface, ground or another
electrode which is connected to a different machine

free of damage

.

.

Ÿ

Ÿ

Protect yourself from electric shock by insulating yourself from work and ground.
Use non-flammable, dry insulating material if possible, or use dry rubber mats, dry
wood or plywood, or other dry insulating material big enough to cover your full area
of contact with the work or ground, and watch for fire.
Never connect more than

electrode to the

.

one

electrode holder

Ÿ

Ÿ

Ÿ

Ÿ

Turn off the machine, when not in use
Disconnect input plug or

power before working on

machine.

Frequently inspect input power cord for damage or bare wiring - repair or replace
cord immediately if damaged.
Be sure

ground

.

swtich off the

the

that the machine is properly

ed.

HOT PARTS CAN CAUSE SEVERE BURNS

Ÿ

Ÿ

Ÿ

Do not touch hot parts
Allow cooling time before servicing

hot parts, use appropriate tool, insulating gloves and fireproof clothes.

.

.

If needed to hold

OBEY ALL THE SAFETY RULES

STATED IN THE MANUAL!

Summary of Contents for MONOSTICK 200 PFC

Page 1: ...www oerlikon com tr MONOSTICK 200 PFC...

Page 2: ...ND OPERATION 2 1 UPON RECEIPT AND CLAIMS 2 2 INSTALLING AND WORKING RECOMMENDATIONS 2 3 CONNECTIONS FOR MMA WELDING 2 4 CONNECTIONS FOR TIG WELDING 3 MAINTENANCE AND TROUBLESHOOTING 3 1 PERIODIC MAINT...

Page 3: ...qualified persons Wear dry insulating gloves and body protection Do not touch electrode with bare hand Do not wear wet or damaged gloves and body protection Do not touch live electrical parts Never to...

Page 4: ...ible If gas cylinders are grouped in a different area make sure that it is a well ventilated area When not being used turn off the main cylinder valve and watch out for gas leakage Shielding gasses su...

Page 5: ...that could give rise to explosions Welding equipments warms up so never position them on flammable surfaces Welding sparks can cause fire For that reason keep extinguishing means such as fire extingu...

Page 6: ...Do not block airflow t unit Do not filter airflow to unit without the approval of manufacturer hrough the ARC WELDING CAN CAUSE INTERFERENCE Electromagnetic energy arising during welding and cutting...

Page 7: ...ing cables up to 25 mt The machine is fan cooled and thermally protected against over heating 200 PFC Thanks to its PFC technology y 40 less than the inverters without PFC and the magnetically control...

Page 8: ...Voltage Welding Current Range Rated Welding Current Protection Class Rated x x 20 20 Power Factor 20 Fuse Cooling Method Dimensions L W H Weight Standards and Approvals V kVA A V A A A mm kg DC DC DC...

Page 9: ...and rainy if this is a must protect the welding area with curtains mobile screens or tents se suitable welding fume extraction systems Use breathing apparatus if there is a risk of inhaling in confin...

Page 10: ...itive welding socket Connect TIG orch to the negative of the machine 5 6 Figure 3 Connecting Gas Cylinder 9 MONOSTICK 200i PFC SWITCH ON the machine via power switch and check if power LED lights up a...

Page 11: ...fan is working but the machine does not weld turn off the machine for 1 minute then turn it on again and try to weld If it still doesn t weld 3 3 2 contact to your authorized technical service 10 Cle...

Page 12: ...t Adjustment Potentiometer Thermic Error LED Red Power LED Green Power Switch NO K405000146 7 K4050001 K405000143 K40500014 A43080000 A43080000 A310100008 42 1 2 A229500001 A410801001 A250200017 SPARE...

Page 13: ...12 MONOSTICK 200i PFC ELECTRICAL DIAGRAM APPENDIX 2 Earth Earth Earth Current Front Panel Welding 5mm Green 5mm Red Thermic Relay Thermic Thermic...

Page 14: ...Made in T RK YE OWM 06 24 2013 90 236 226 27 00 90 236 226 27 28 Organize Sanayi B lgesi 5 K s m Yal n zaras Caddesi No 1 45030 MAN SA www magmaweld com FACTORY...

Reviews: