Set Wire
Wire 0 - 25
Spot
Set Voltage
Voltage 0 - 25
Crater Open
Pre Gas
Crater Closed
Pre-Gas
Pnt Mode
On
Pnt Mode
Off
Post Gas
Pre-Gas
Crater
Crater
Burn Back
Burn Back
Burn Back
Post Gas
Post Gas
Post Gas
Burn Back
Post Gas
Set Voltage
Voltage 0 - 25
Crater Open
Pre Gas
Set Wire
Wire 0 - 25
Crater Closed
Pre-Gas
Slow Release
Off
Slow Release
On
Slow Release
On
Slow Release
Off
3.4 Arc Length Adjustment (ArC)
When you press and hold the adjustment pot (5) for 3 seconds, the arc length function will be active.
The factory setting is 0.0. You can change the arc length adjustment in the range of + 7 / -7 by turning the same
pot to the right or left. As it goes t7, the wire approaches the nozzle, the arc length increases. As it goes
towards -7, the wire approaches the welding metal and the arc length decreases. After the desired setting is
made, the setting is exited by pressing the same pot.
3.5 MIG Curve
Value Range
Factory Setting
2- Position MIG
0,0 - 9,9 sec
0,1 sec
0,0 - 9,9 sec
0,0 sec
Method / 2 / 4
2
25 - 0 - 25
0 step
Thickness
Wire Type
Trigger
0,6 - 20,0 mm
1,0 mm
Arc On Time
Arc Off Time
0,0 - 9,9 sec
0,1 sec
Wire Diameter
0,6 - 2,4 mm
1,0 mm
MIG/MAG - MMA -
LIFT TIG
MIG / MAG
0,2 - 9,9 sec
0,2 sec
Steel, AlMg, FCW, AlSi, FCW-M, CuSi, CrNi, CuAl
4- Position MIG
CO
₂
, Ar/5-10 CO
₂
, Ar/15-25 CO
₂
, Ar/2.5 CO
₂
, Ar/10-15 CO
₂
, Argon
Synergic / Smart / Classic
Active / Passive
Passive
Method
Pre-Gas
Burn Back
Post Gas
Gas Type
Crater
Mode