MAGMATIC Prisma Driver 8 User Manual Download Page 4

4

 

G E N E R A L   I N F O R M A T I O N

 

INTRODUCTION

 

Please read and understand the instructions in this manual carefully and thoroughly before 
attempting to operate this device. These instructions contain important safety and use information. 

UNPACKING 

Every device has been thoroughly tested and has been shipped in perfect operating condition. 
Carefully check the shipping carton for damage that may have occurred during shipping. If the 
carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to 
install and operate the device have arrived intact. In the event damage has been found or parts are 
missing, please contact our customer support team for further instructions. Please do not return this 
device to your dealer without first contacting customer support. Please do not discard the shipping 
carton in the trash. Please recycle whenever possible. 

BOX CONTENTS 

Driver Unit (x1) 

Twist Locking Power Cable (x1) 

CUSTOMER SUPPORT 

Contact MAGMATIC Service for any product related service and support needs. 
Also visit 

forums.elationlighting.com 

with questions, comments or suggestions. 

ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 
323-582-3322 |

 

Fax 323-832-9142 | 

[email protected]

 

ELATION SERVICE EUROPE - Monday - Friday 08:30 to 17:00 CET   
+31 45 546 85 63 | Fax +31 45 546 85 96 | 

[email protected]

 

REPLACEMENT PARTS

 please visit 

parts.elationlighting.com 

 

I M P O R T A N T   N O T I C E !  

THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. 
DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR 
MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS 
TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND 
GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND 
ARE NOT SUBJECT TO ANY WARRANTY CLAIMS AND/OR REPAIRS. 

 
 
 
 
 

Summary of Contents for Prisma Driver 8

Page 1: ...Prisma Driver 8 User Manual...

Page 2: ...ndirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligent assembly installation r...

Page 3: ...Warranty USA Only 5 Warranty Returns USA Only 6 Safety Guidelines 7 Maintenance Guidelines 9 Driver Overview 10 Installation Instructions 11 System Menu 14 DMX Channel Functions Values 17 Dimmer Mode...

Page 4: ...port Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS Driver Unit x1 Twist Locking Power Cable x1 CUSTOMER SUPPORT Contact MAGMATIC Service for any...

Page 5: ...instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magm...

Page 6: ...ed freight pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of...

Page 7: ...acturer s warranty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY R...

Page 8: ...power cord or any of its connectors are damaged replace it immediately with a new one of similar power rating DO NOT block any air ventilation slots All fan and air inlets must remain clean and free...

Page 9: ...ician Should you need any spare parts please order genuine parts from your local MAGMATIC dealer Please refer to the following points during routine inspections A detailed electrical check by an appro...

Page 10: ...I V E R O V E R V I E W 1 Mounting Points 2 Display Screen 3 Mode Button 4 Down Button 5 Up Button 6 Enter Button 7 5 pin DMX In 8 5 pin DMX Out 9 Fuse T3A 250V 10 Power In 11 Power Out 12 Signal Out...

Page 11: ...ounting a single device or multiple interconnected devices for custom matrix designs to any metal truss structure or placing the device s on any surface a professional equipment installer MUST be cons...

Page 12: ...x connector into the desired signal output port on the driver making sure that the latch on the Phoenix connector engages with the signal output port Tighten the two screws located to each side of the...

Page 13: ...S T A L L A T I O N I N S T R U C T I O N S MOUNTING The driver may be secured to a surface or mounting rail by using the four 4 mounting points located on the mounting brackets on either side of the...

Page 14: ...e different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that requires adjusting press the ENTER button to activate that field and use the UP and DOWN buttons...

Page 15: ...splay On Off 30 second screen time out Key Lock On Off Lock screen keys Flash On Off Display screen will flash when DMX connection is absent Invert Off On Flip screen display Dim Mode Standard Stage T...

Page 16: ...Off Restore factory default settings INFO TimeInfo Current Current fixture run time hours Total Total fixture run time hours Last Clear current fixture run time Password 050 or 060 Clear On Off Model...

Page 17: ...9 CH STANDARD MODE Magmatic Prisma Driver 8 DMX Channels Functions Supports Software Versions 1 01 CHANNEL VALUE FUNCTION 1 000 255 LED Signal Output 1 2 000 255 LED Signal Output 2 3 000 255 LED Sign...

Page 18: ...ignal Output 2 3 000 255 LED Signal Output 3 4 000 255 LED Signal Output 4 5 000 255 LED Signal Output 5 6 000 255 LED Signal Output 6 7 000 255 LED Signal Output 7 8 000 255 LED Signal Output 8 9 000...

Page 19: ...age Dimmer Delay Time continued from prev page 124 0 3 s 125 0 4 s 126 0 5 s 127 0 6 s 128 0 7 s 129 0 8 s 130 0 9 s 131 1 0 s 132 1 5 s 133 2 0 s 134 3 0 s 135 4 0 s 136 5 0 s 137 6 0 s 138 7 0 s 139...

Page 20: ...D I M M E R M O D E S Select desired DIMMER MODE Standard Stage TV Architectural Theatre Stage2 Output 0 100 Output 0 100 Output 0 100 Output 0 100 DMX DMX DMX DMX LINEAR SQUARE INVERSE SQUARE S CURV...

Page 21: ...Locking 5pin XLR Connector In Out IP65 Locking Power Connector In Out With Wired Digital Communication Network SIZE WEIGHT Length 8 9 in 226mm Width 7 4 in 188mm Vertical Height 3 19 in 81mm Weight 5...

Page 22: ...22 D I M E N S I O N A L D R A W I N G S Drawings not to scale...

Page 23: ...23...

Page 24: ...SKU PSD108 EU 1237000230 UPC 810008261194...

Reviews: