Appendix C. CHANGING THE OPERATING TEMPERATURE OF THE DISPLAY CASE 

Operating temperature is set up by changing the value of the parameters in the display case controller: 

- “

FSt

“ (pallet temperature); 

- “

Set

“ (temperature of the display case upper space). 

To change the value of the “

FSt

“ parameter (upper place temperature) do the following: 

Enter the 

Programming

 menu by pressing and holding the “

set

“ button of the controller for at least 5 seconds. 

The label of the first menu folder “

CP

“ will appear on the display. 

> 5 seconds 
 

 

Use the “

Up

“ and “

Down

“ buttons to scroll through the programming menu folders until the “

FAn

“ folder  

 

While on the folder label “

FAn

“, press the “

set

“ button 

 
 

the first folder parameter will appear on the controller display. 

Use the “

Up

“ and “

Down

“ buttons to switch to the “

FSt

“ parameter. 

 

 

 

Press the “

set

“ button on the “

Fst

“ parameter and you will see its value. 

  

 

 

Set the new temperature value by “

Up

“ and “

Down

“ buttons  

 

Press the “

fnc

“ button

 

 

The entered parameter has been saved.  

Turn off and turn on the display case again, now the case will work with the newly set value of the lower heating 
temperature. 

To change the value of the "

Set

" parameter (tray temperature), it is required the following: 

Turn on the showcase. Press the “

set

“ button on the controller, “

Set

“ will be displayed on the scoreboard. 

 

 

Press the “

set

 

button on the “

SEt

“ parameter and you will see its value. 

 

 

Summary of Contents for BERILL T

Page 1: ...______________________________________________________________________________________________________________________________________________________________________ OPERATION AND MAINTENANCE MANUAL...

Page 2: ...ure to follow the recommendations and instructions contained in this manual Notice All dimensions in drawings are given in mm if not otherwise specified Illustrations may not fully correspond to the m...

Page 3: ...f food products whose storage temperature corresponds to the temperature range of the display case 1 3 DEVELOPMENT AND STANDARDIZATION This equipment has been designed and manufactured in accordance w...

Page 4: ...h as aerosol cans containing flammable mixtures inside this appliance ATTENTION it is strictly forbidden to turn on the display case without grounding and move the display case that is under voltage M...

Page 5: ...00 Infrared lamps W 3 x 300 6 x 300 Lighting type LED Backlight power consumption W 18 36 Rated power consumption per day 1 Basic set of the cabinet light 12h kW h 21 4 42 8 Dimensions Overall dimensi...

Page 6: ...hanical protection devices adapted to the equipment to prevent possible damage for example from the impact of a trolley a polisher a loader etc 4 3 ADJUSTMENT OF THE FRONTAL GLASSES Adjustment of the...

Page 7: ...THE EDGE OF THE GLASS AND AS A RESULT DESTROY IT 5 2 TURNING ON THE DISPLAY CASE Turn on the display case only after carrying out all preparatory works fulfilled by qualified personnel To turn on the...

Page 8: ...ENANCE Before cleaning or maintenance the equipment must be disconnected from the power supply to guarantee the absence of an electric current in the system Purpose of cleaning is to remove pathogenic...

Page 9: ...EQUIPMENT S LIFE CYCLE At the end of a useful life of the equipment we recommend the following Make it unserviceable for example cut power cable Remove glass shutters or other elements which may be da...

Page 10: ...9 Appendix A ELECTRIC WIRING DIAGRAM BERILL T 125...

Page 11: ...10 Appendix B ELECTRIC WIRING DIAGRAM BERILL T 250...

Page 12: ...menu folders until the FAn folder While on the folder label FAn press the set button the first folder parameter will appear on the controller display Use the Up and Down buttons to switch to the FSt p...

Page 13: ...e will work with the newly set temperature value of the upper space Find below an example of a sequence of actions to change the value of the FSt parameter from 60 C to 80 C 5 seconds Turn off and tur...

Page 14: ...RMS page labeled AL AFd Alarm differential 2 0 1 F Differential activation of the alarm signal HAL Higher ALarm Maximum alarm 90 0 1 F The value of the higher temperature limit DISPLAY page labeled di...

Page 15: ...d and similar electrical appliances Safety Part 2 49 Particular requirements for commercial electric appliances for keeping food and crockery warm is in conformity with the Directives 2014 30 EU Elect...

Reviews: