11
Appendix C. CHANGING THE OPERATING TEMPERATURE OF THE DISPLAY CASE
Operating temperature is set up by changing the value of the parameters in the display case controller:
- “
FSt
“ (pallet temperature);
- “
Set
“ (temperature of the display case upper space).
To change the value of the “
FSt
“ parameter (upper place temperature) do the following:
Enter the
Programming
menu by pressing and holding the “
set
“ button of the controller for at least 5 seconds.
The label of the first menu folder “
CP
“ will appear on the display.
> 5 seconds
Use the “
Up
“ and “
Down
“ buttons to scroll through the programming menu folders until the “
FAn
“ folder
While on the folder label “
FAn
“, press the “
set
“ button
the first folder parameter will appear on the controller display.
Use the “
Up
“ and “
Down
“ buttons to switch to the “
FSt
“ parameter.
Press the “
set
“ button on the “
Fst
“ parameter and you will see its value.
Set the new temperature value by “
Up
“ and “
Down
“ buttons
Press the “
fnc
“ button
The entered parameter has been saved.
Turn off and turn on the display case again, now the case will work with the newly set value of the lower heating
temperature.
To change the value of the "
Set
" parameter (tray temperature), it is required the following:
Turn on the showcase. Press the “
set
“ button on the controller, “
Set
“ will be displayed on the scoreboard.
Press the “
set
“
button on the “
SEt
“ parameter and you will see its value.