48
Versorgungsbatterie
Pure Sine Inverter
Stromnetz/Generator
Netzvorrangschaltung
230 V Verbraucher
4�8
Operate Devices with two AC Voltage Sources
Never operate two AC voltage sources in parallel on one
consumer. This can irreversibly damage the inverter. If, for
example, shore power is to be supplied in parallel (e.g. also via
a MAGIRA electric generator), please use a network priority
circuit. Depending on the model, this automatically switches
between the two devices without affecting the connected de-
vices. In this way a backup system can also be set up.
Wrong:
Right:
230 V Verbraucher
Versorgungsbatterie
Pure Sine Inverter
Stromnetz/Generator
Kurzschlussgefahr!
Risk of Short Circuit!
230 V Consumer
Supply Battery
230 V Consumer
Supply Battery
Pure Sine Inverter
Power Grid/Electric Generator
Network Priority Circuit
Pure Sine Inverter
Power Grid/Electric Generator