![MAGINON IPC-1A Instruction Manual Download Page 46](http://html1.mh-extra.com/html/maginon/ipc-1a/ipc-1a_instruction-manual_3543436046.webp)
44
Sensitivity:
Determine the sensitivity for the motion sensing by entering a value between
0 and 9. The higher the value, the higher the motion sensing sensitivity.
Compensation of light changes
: This option can be selected to prevent the movement
sensing from being influenced by changing light conditions.
Recognition at digital input:
If an alarm message is triggered via the alarm connection,
this can be accepted by the WiFi Network Camera if this option has been activated.
Alarm level
: Determines whether an alarm is triggered if no voltage is applied to the alarm
input
(setting
low
) or if voltage is applied (setting
high
).
Report at digital output
: Any alarm message at the WiFi Network Camera is forwarded via
the digital output if this option has been activated.
Alarm level:
Determine whether the alarm is triggered at the digital output by an applied
voltage
(setting
high
) or by a cessation of the voltage (setting
low
).
Report to email
: Activate this option if an email message should be triggered in case of an
alarm
incident.
Report to FTP
: Activate this option if images should be saved to the FTP server in case of
an
alarm.
Interval:
Determine at what interval images should be saved to the FTP server in case of
an alarm. The value is in seconds.
Report to HTTP
: Activate this option if an HTTP address should be contacted in case of an
alarm
incident.
URL
: Determine which HTTP address should be contacted in case of an alarm incident.
Click on “
Save
” to accept changes to the settings. Changes to the alarm settings are accepted
without the WiFi Network Camera having to be restarted.