MKG SERIES GAS GRIDDLE INSTALLATION & OPERATION
6
1.6.2.
Gas Settings:
Orifices are sized to provide proper gas flow to the rated
BTU/hr for each model. Regulator pressure must be measured
and adjusted before the unit goes into service, following
installation and when operational performance is in question.
Gas Type
BTU/hr(kW)
Per Burner
Manifold
Pressure
WC"
(Matchless)
Manifold
Pressure
WC"
(All Others)
Natural
15,000(4.4)
4.0"(10.1cm)
4.5"(11.4cm)
Propane
15,000(4.4)
10.0"(25.4cm)
10.0"(25.4cm)
FIGURE #3
2.
OPERATION SECTION:
Ensure that a proper installation has been performed on the appliance and that all warnings, cautions, and notices contained in
this manual have been read, understood and adhered to before proceeding.
2.1.
LIGHTING INSTRUCTIONS:
2.1.1.
Snap Action Thermostat Appliances:
A.
Turn all thermostat knobs to the “
OFF
” position.
B.
Open front door of the griddle, turn the manual gas
shut off valve to the “
ON
” position.
C.
Press and hold the leftmost
RED
pilot button, see
detail Method A at right, and light the leftmost pilot
with a flame source, through the left pilot hole, or
depress the Piezo ignition control (If Provided). With
pilot burning, keep the
RED
pilot knob depressed for
45 seconds or until pilot remains lit automatically.
D.
Repeat steps A, B, and C for all remaining pilots.
E.
Operate thermostats by turning knobs clockwise to the desired temperature and insure that burners light
properly by looking through the pilot holes provided in the front panel.
NOTICE:
If appliance contains more than one pilot, the leftmost pilot
MUST
be lit first or the other pilot
WILL NOT LIGHT
.
2.1.2.
Solid State and Electric Thermostat Appliances:
A.
Turn all thermostat knobs to the “
OFF
” position, or the
lowest possible temperature setting.
B.
Turn the Manual gas shut off valve to the "
ON
" position,
this valve is located at the rear of the unit, see Figure #2.
C.
Turn the
RED
"I/O" switch to the “
I
”(ON) position for
all desired Thermostats to be operated, See detail
Method B at right. When the Pilot ready (Amber) light
illuminates, the pilot(s) are ready to operate the main burners.
D.
Repeat for all thermostat controls to be operated.
E.
Operate thermostats by turning knobs clockwise to the desired temperature and insure that burners light
properly by looking through the pilot holes provided in the front panel.
The
RED
"I/O" switch will illuminate when the thermostat calls for heat.
CAUTION
If Pilot Ready light(s) does not illuminate, Turn all Thermostat "I/O" switches for that pilot to “O”(OFF), wait five
minutes before attempting to re-light.
If Pilot(s) extinguish or gas supply is interrupted, turn thermostat knobs and the gas shut off valve to the "
OFF
"
position and wait 5 minutes before attempting to re-light.