Grace Timer & PEM7 timer 

YELLOW-#3 terminal

BLACK-#1 terminal

BLUE-#4 terminal

Dixmor  DigitTimer 3 

YELLOW-red wire on timer

BLACK-green wire on timer

BLUE-brown wire on timer

Ginsan GS7 timer 

YELLOW-24VAC #3 terminal

BLACK-24VAC #1 terminal

BLUE-#4 terminal

3)

DISPLAY PANEL AND BUTTONS 

The iCoin utilizes a display panel and pushbuttons for setup and self-diagnostics. 
The display panel has several indicator lights that show power status, which coins 
the iCoin is currently accepting, and setup information regarding tokens. The 
pushbuttons allow one to change the coins that are to be accepted and to set the 
tokens (if any) that the iCoin is to accept.

4)

DISPLAY DURING POWER UP  

During the initial power up sequence, the iCoin displays the current settings for 
several options. For the first second after power up, the 5 indicator lights 1, 2, 4, 8, 
and 16 for #pulses for Selected Token show the current Token Sensitivity setting, 
the Pulse Speed setting, and the Preprogrammed Coins Number of Pulses Setting. 
Immediately following this, indicator lights 1 and 2 for #pulses for Selected Token 
will display for  approximately 1 second to show normal power up. Finally, the 
normal operating display will show the current coin and token settings.

For more information on the Token Sensitivity setting, the Pulse Speed setting, and 
the Preprogrammed Coins Number of Pulses setting, see the appropriate section 
that follows.

5)

CANADIAN QUARTER, LOONIE AND TOONIE SELECTION 

The iCoin is preprogrammed to accept one or all of Canadian quarter, $1 (loonie) 
and $2 (toonie) coins. Once the iCoin is powered up, the display panel shows which 
coins the iCoin is activated to accept. For example, if the indicator lights for Cdn-

Summary of Contents for iCoin CP900

Page 1: ...iCoin Model CP900 v 1 3 Electronic Multi Coin Acceptor Instruction Manual ...

Page 2: ......

Page 3: ...ow and black wires of the iCoin are for supply voltage of 24VAC Yellow is and black is ground Electronic pulsing units have a blue and purple wire The blue wire is a DC switch used for pulsing that will sink a maximum of 200mA at 5 40VDC to black ground The purple wire is an AC switch used for pulsing that will sink a maximum of 500mA up to 600VAC to black ground Relay pulsing units have two red w...

Page 4: ...ettings for several options For the first second after power up the 5 indicator lights 1 2 4 8 and 16 for pulses for Selected Token show the current Token Sensitivity setting the Pulse Speed setting and the Preprogrammed Coins Number of Pulses Setting Immediately following this indicator lights 1 and 2 for pulses for Selected Token will display for approximately 1 second to show normal power up Fi...

Page 5: ... pulse will be sent to the timer for the lowest value coin that the iCoin is set to accept Multiple pulses will be sent to the timer for higher value coins that are accepted Figure 5 3 shows the different coin selection settings and the corresponding number of pulses that will be sent to the timer Ensure that your timer is setup correctly based on the number of pulses that the iCoin will send for t...

Page 6: ...w move the indicator light to TokenA The indicator lights 1 2 4 8 and 16 for pulses for Selected Token show the total number of pulses that will be sent when the currently selected token is accepted The total number of pulses that will be sent is the sum of all the indicator lights 1 2 4 8 and 16 for pulses for Selected Token that are lit If all indicator lights for pulses for Selected Token are o...

Page 7: ... the least discriminatory is shown by the 2 indicator light medium by the 4 indicator light and high by the 8 indicator light The higher the sensitivity the more strict the iCoin will be in accepting tokens In normal use the sensitivity setting of the iCoin may be left at medium However if you find that a particular token of yours has variations in its metallic content which cause the iCoin to acc...

Page 8: ...Cdn quarter 1 coin and 2 coin is dependent on which of these coins are enabled and disabled This setting for the number of pulses for the preprogrammed coins is called the variable pulse setting It is possible to change this setting so that the iCoin will always send 1 pulse for a quarter 4 pulses for a 1 coin and 8 pulses for 2 coin regardless of which coins are enabled This setting for the numbe...

Page 9: ...uck in the coin acceptor the iCoin CP900 features full access to the internal coin path By gently pulling back on the right side of the display panel as shown in figure 10 1 the hinged door will pull back to allow cleaning and removal of damaged coins figure 10 1 ...

Page 10: ...ddition when learning tokens record the details of each token on the following lines SERIAL ___________________________________ TokenA Description ____________________________________________ TokenB Description ____________________________________________ TokenC Description ____________________________________________ ...