Page 8
2.1.3. Lighting Procedure (Remote Control)
1. Press the bottom button on the remote
handset until clicking is heard on the
valve, and the gas rate adjustment knob
is at the off position.
2. With gas available at the valve press the
IGNITION KNOB in and turn it
anticlockwise to the pilot flame position.
A click of the piezo igniter will be heard
and a spark will appear at the electrode.
At the same time the gas will flow to the
pilot burner and should be ignited by the
spark. Repeat the procedure until the
pilot flame is established.
3. Keep the knob pressed in for a further 10
- 12 seconds and slowly release it. The
pilot flame should stay alight. If the
flame goes out repeat the procedure
above to establish the pilot.
4. If the spark unit fails to light the pilot, the
appliance may be lit manually by
applying a lighted match or taper to the
pilot jet and following the above
procedure.
5.
Turn the IGNITION KNOB
anticlockwise to the Main Burner
Operation position as shown in Figure
10.
6. Using the HANDSET (as shown in
Figure 11
) press and hold
both the top
and the small button together
until the
main burner goes to full rate and clicking
can be heard from the valve. During this
process the main burner will ignite from
the pilot.
7. By pressing the two buttons together (to
increase the gas rate) and the lower
button only (to decrease the gas rate)
the valve can be manipulated to select
the desired gas rate between maximum
and minimum. By pressing the buttons
in short bursts you will be able to adjust
the gas rate in small steps.
8. To turn the fire off, continuously press
the lower button until the flame dies
down and clicks can be heard from the
valve. Release the button as soon as
the clicks are heard.
9. The fire can safely be left in this position
at all times, however to prevent
unauthorised or accidental use (say by
children) it is recommended to turn the
IGNITION KNOB to the pilot flame
position by turning it 90 degrees
clockwise. To turn the pilot off, turn the
IGNITION KNOB fully clockwise.
NOTE:
The clicking sound
made by the valve is the
operation of the valve clutch,
and indicates either maximum
or minimum positions.
IGNITION
KNOB
FULL RATE
POSITION
MAIN BURNER
OFF POSITION
PILOT ONLY
POSITION
MAIN BURNER
OPERATION
GAS RATE
ADJUSTMENT
KNOB
Figure 10 – Gas Valve
Press these
two buttons
together to
increase
gas rate
Press this
button to
decrease
gas rate
Figure 11 - Handset Operation
NOTE:
No attempt should be
made to relight the fire for at
least 3 minutes after the pilot
flame has been extinguished
either intentionally or
unintentionally.