Preparing to install the refrigerator.

Door Reversal

1. Remove the two screws from under the screw caps located on the top cover.

2. Remove the two screws from the back of the top cover and remove top cover.

3. Remove the top hinge by removing the two screws, as shown.

4. Remove the freezer door by lifting off of the middle hinge.

5. Remove the J-shaped hinge support on the bottom of the freezer door.

6. Install new J-shaped hinge support on the opposite side of the freezer door bottom. 

The new J-shaped hinge support and mounting screw are located in a zip lock bag that 

is shipped with the refrigerator. 

Installation Instructions

Preparing to install the refrigerator.

Read these instructions completely and carefully.

Refrigerator Location

• 

Do not install the refrigerator where the temperature will go below 50°F (10°C) 

because it will not run often enough to maintain proper temperatures.

• 

 Install it on a floor strong enough to support it fully loaded.

• 

 Do not install it closer than 5”(13 cm) next to a range.

• 

 Do not install it in a recessed area.

• 

 Do not build in the refrigerator.

Clearances

Allow the following clearances for ease of installation and proper

air circulation.

Sides

 113) “2/ mm)

Top

 2” (51 mm)

Back

 2” (51 mm)*

*From the rear cabinet surface to the wall

Leveling Legs

 (on some models)

Adjustable legs at the front corners of the refrigerator should be set so the refrigerator 

is  firmly  positioned  on  the  floor  and  the  front  is  raised  just  enough  that  the  door 

closes easily when opened about halfway. 

To adjust the leveling legs

, turn the legs 

counterclockwise to lower

 the refrigerator,

 clockwise toraise

 it.

Summary of Contents for MCSF-5585BSS

Page 1: ...Please read the following instructions completely before operating this appliance INSTRUCTION MANUAL REFRIGERATOR MCSR 6085W MCSR 6085B MCSR 6085BSS MCSR 5585W MCSR 5283W MCSF 5585BSS ...

Page 2: ...ricefromsurfacesoftherefrigeratorand orfreezercompartment Doingsocouldpuncturethecoolingcoil causingtheunittoloseitsabilitytomaintaincoldtemperaturesandvoidingthewarranty SeetheCareandCleaningsectionforinstructionsondefrostingtherefrigeratorand or freezercompartment ...

Page 3: ...ECTRICITY 4 operationinstruction 5 ControlSettings 5 Abouttherefrigeratorfeatures 6 Careandcleaningoftherefrigerator 6 Careandcleaningoftherefrigerator 6 Careandcleaningoftherefrigerator 7 Preparingtoinstalltherefrigerator 8 Troubleshootingtips 10 Safetyprecautions 12 ...

Page 4: ...sibility andobligationtohaveitreplacedwithaproperlygrounded3 prongwalloutlet The refrigerator should always be plugged into its own individual electrical outlet whichhasavoltageratingthatmatchestheratingplate SafetyInstructions IMPORTANTSAFETYINFORMATION READALLINSTRUCTIONSBEFOREUSING UsethisapplianceonlyforitsintendedpurposeasdescribedinthisOwner sManual SAFETYPRECAUTIONS Whenusingelectricalappli...

Page 5: ...hemilktest Placeacontainerofmilkonashelfandcheckitadaylater Ifthemilkis toowarmortoocold adjustthetemperaturecontrol Afterchangingthecontrol allow This provides the best performance and also prevents overloading house wiring circuitswhichcouldcauseafirehazardfromoverheatedwires Never unplug your refrigerator by pulling on the power cord Always grip plug firmlyandpullstraightoutfromtheoutlet Repair...

Page 6: ...nside To help prevent odors leave an open box of baking soda in the refrigerator Unplug the refrigerator before cleaning If this is not practical wring excess moisture out of sponge or cloth when cleaning around the control Use warm water and baking soda solution aboutatablespoon 15ml ofbakingsodatoaquart 1liter ofwater Thisbothcleans andneutralizesodors Rinseandwipedry Otherpartsoftherefrigerator...

Page 7: ...er unscrew the lens and pull horizontally until the lens is removed Gently unscrew the light bulb and replace with a bulb of 15 watts orless Careandcleaningoftherefrigerator Defrosting Defrost whenever frost on the wall of the Freezer compartment becomes 164 4 mm thick Never use a sharp or metallic instrument to remove frost as it may damage the cooling coils A punctured cooling coil will cause se...

Page 8: ...lyandcarefully RefrigeratorLocation Do not install the refrigerator where the temperature will go below 50 F 10 C becauseitwillnotrunoftenenoughtomaintainpropertemperatures Installitonafloorstrongenoughtosupportitfullyloaded Donotinstallitcloserthan5 13cm nexttoarange Donotinstallitinarecessedarea Donotbuildintherefrigerator Clearances Allowthefollowingclearancesforeaseofinstallationandproper airc...

Page 9: ...gerator 12 Re install the adjustable legs Insure that the smaller leg is on the same side as the bottomhinge 13 Placethefreshfooddooronthebottomhinge 14 Place the bottom peg of the middle hinge in the fresh food door Re install middle hinge Make sure the fresh food door is aligned with the refrigerator cabinet before tighteningscrews 15 Place the freezer door on the top peg of the middle hinge Pla...

Page 10: ...10 Troubleshootingtips Savetimeandmoney ...

Page 11: ...Safety precautions ...

Page 12: ...12 Safetyprecautions ...

Page 13: ...n Thickinsulationforenergyefficiency SystemFlowChart 1 SchematicdiagramofSystemFlowChart 2BriefDescriptionofSystemFlowChart Allmodelsareadirectcoolingsingle systemrefrigeratororfreezer Whenthe refrigeratororfreezerisjustpoweredon therefrigerantflowsinthesequence 1 2 3 4 5 1 ...

Page 14: ...ooting 1 Nocooling CircuitDiagram 1SchematicCircuitDiagram BriefDescriptionofControlPrinciple Amechanicaltypeofallthecontrolisgenerallyadopted Thethermostatdirectlycontrolsthestartandstopofcompressor and hencetherefrigeratortemperature ...

Page 15: ...15 3Coolingcapacityisinsufficient 2Thecompressordoesn tstop ...

Page 16: ...ststoppedrunning arumblingsoundcanbeheardfrominsideits evaporator Thisisasoundcausedbytheflowingofrefrigerantintheevaporatortubing Because the pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 Aclicksoundcanoftenbeheardfromtherefrigerator Thisisa normalsoundproducedbythepull ...

Page 17: ... inside the compressor this means that some moving parts have loosened note to differentiate this sound from thoseformedduringstartingorstoppingthecompressor 4 For the direct cooling refrigerator a kind of irregular crack sound can be often heard when the compressor is running for a certain period of time or has just stopped its running Thissoundiscausedbythestressreliefduetoexpansionandcontractio...

Page 18: ...tothosepartsthatareliableto leak check main connection points for oil seepage and tubing for cracks If there is no b ListentothesoundcausedbytheflowingofgasintheevaporatorOpentherefrigerator doorwhilethecompressorisinoperation inclineyourearandlistenattentivelythegas flow sound inside the evaporator If it sounds like gentle whistling accompanied by a sound similar to water flowing this is the soun...

Page 19: ...or the heat conduction effect will be severer leak point charge the system with nitrogen and detect leak points with the commonlyadoptedmethod repairthem evacuate chargethesystemwithrefrigerant andthenturnontherefrigeratortomakeatestrun 2 Toomuchrefrigerantchargedintothesystem AnalysisofTrouble a In case the amount of refrigerant charged into the system exceeds its nominal capacity the superfluous...

Page 20: ...ently sometimes therefrigeratorworkswell andsometimesnotwell Inorder todeterminewhetheritiscloggedwithice heatthesuspiciouspointswithhotwaterto make ice melt and after a while if a gas flowing sound resulting from an abrupt gush is heard and the gas suction pressure rises as well itcan be confirmed that the trouble is severelyaffected thuscausingapoorrefrigeratingeffect RemedyItisquitedifficultto ...

Page 21: ...he system with a properquantityofrefrigerant b Air left in the system Analysis of Trouble The residual air in the system will circulate togetherwiththerefrigerantinthesystem Themajorsymptomscausedbythisresidual causedbyiceclogging RemedyIfthereistoomuchmoistureintherefrigeratingsystem itisadvisabletoreleasetherefrigerant purgethetubingwithnitrogen andthencharge the system with the filtered refrige...

Page 22: ...due to the leakage of temperature airishighergasdischargepressure higherdischargedgastemperature thegasdischarge tubing is considerably hot when you feel it with your hand and poorer refrigerating effect Furthermore the gas discharge pressure will exceed its normal value when the compressor has run for a period not too long thus making the protective relay actuate andbringtoastoppage RemedyCheckup...

Page 23: ...rationtemperatureinthesystemistoo high thetemperaturesensingagentinthetemperaturesensorisalsohotter therefore sensing agent from the temperature sensor Remedy Remove the relay cover to check up its contacts if they are open this means that the original setting is not properly set ortemperaturesensingagenthasleakedoutofthetemperaturesensor Trytoturnthe adjusting stem of this value in the direction ...

Page 24: ...ndthattherefrigerantinthesystemisinsufficientinquantity recharge it with refrigerant In case clogging occurs disassemble the part where it is blocked If the evaporation temperature is too high settle this problem with an appropriatequantityofrefrigerant 3 No stoppage of compressor due to damaged heat insulation layer inside case body and ordoorsealAnalysisofTroubleWhentheheat insulationlayerinside...