Installation
MultiView™ II XRTx Installation and User Guide
13
4.3
Configuration
This section describes how to configure the following settings:
•
User-configurable settings
•
DDC settings
4.3.1
User-Configurable Settings
The XRTx has a number of configurable operating parameters, and the factory-default settings will work in most
applications. However, some applications may require configuration changes. Nearly all settings are available
from the front-panel buttons/LEDs. The enclosure does not need to be opened unless an option module is being
installed or removed, or settings specific to the option module need to be changed.
The DDC MODE selection is done in NORMAL operating mode (CFG indicator is off).
•
To change the DDC operating mode, press the DDC MODE button.
For all other configuration settings, the XRTx must be in CONFIG mode (CFG indicator is on). Once in CONFIG
mode, any changes are effective immediately and are saved in non-volatile memory.
To enter configuration-mode-1:
•
Press CFG button once. The CFG indicator will turn on, confirming you are in configuration-mode-1.
Once in this mode, the LED indicators 1-8 will display the current settings.
To enter configuration-mode-2:
•
Press CFG button twice. The CFG indicator will flash, confirming you are in configuration-mode-2.
Once in this mode, the LED indicators 1-8 will display the current settings.
To exit configuration-mode:
•
Leave the buttons untouched for 10 seconds. The CFG indicator will turn off (normal-mode).
To quickly reset all user-configurable options back to factory-default settings:
1. Disconnect the DC power cable (or AC power).
2. Press and hold the CFG button.
3. Connect the DC power cable (or AC power). All LEDs blink 3 times, indicating all settings are now changed
back to factory-defaults.
4. Release the CFG button.