HOMEOWNERS MANUAL FOR SOLAR POOL HEATING   

2

This Homeowners Manual will go over the basic operations of your system, system 

shutdown/opening, maintenance and troubleshooting. If you have any issues with 

your system please contact your installer or contact us directly at: 

800.79.SOLAR

OPERATIONAL CONCEPT  

Pool water is circulated through the solar pool heating collectors using your existing pool pump 
(or solar booster pump, if one exists). As water moves through the solar pool heating collectors 
it is heated by sun before returning to the pool. Upon system startup air will purge from the 
solar pool heating collectors and out through the pool return jets. This is normal operation and 
bubbles will usually stop within 1-3 minutes after initial startup.

CONTROLS

Unless the system is manual in design it is controlled using an electronic differential controller. 
The differential controller measures the temperature difference between the pool water and 
the roof where the solar pool heating collectors are located using two temperature sensors. 
When the temperature on the roof reaches a certain threshold above the temperature of the 
pool water a motorized diverter valve is triggered and diverts water to the solar pool heating 
collectors. When the desired pool temperature has been reached, or sufficient solar radiation 
is no longer available, the diverter valves turns back and sends water directly back to the pool, 
bypassing the solar pool heating collectors.  

Detailed instructions on how to set your desired water temperature and turn the system on 
or off can be found in your specific controller manual. If your system is controlled using your 
existing pool automation system, then that manual will provide steps on setting up the solar 
pool heating system controls. In general manuals are available online at manufacturer websites. 
Please note that your pool pump must be timed to run during daylight hours for your solar 
system to operate.  

Thank you for your recent purchase of a SunStar

Solar Pool Heating System from UMA Solar. 

BASIC OPERATION OVERVIEW

Summary of Contents for UMA Solar Sunstar Solar Pool Heating

Page 1: ...lease take care to avoid hazards such as electrical wires and loose shingles If you have any product or installation questions contact your SunStar representative SunStar is distributed in the United States by UMA Solar a Magen eco Energy Company 800 79 SOLAR 76527 www umasolar com 2021 ...

Page 2: ...ween the pool water and the roof where the solar pool heating collectors are located using two temperature sensors When the temperature on the roof reaches a certain threshold above the temperature of the pool water a motorized diverter valve is triggered and diverts water to the solar pool heating collectors When the desired pool temperature has been reached or sufficient solar radiation is no lo...

Page 3: ...mp must shut off at least 30 minutes prior to any freeze event Typically freezes occur over night and most pumps with solar pool heating systems are timed to run anywhere from 8am 6pm Most pool equipment is protected against freezing using recirculation freeze protection so in the event of a freeze the pump will reengage and the solar diverter valve should not allow water into the solar loop 2 Rec...

Page 4: ...uring the period of winterization keep the manual isolation valves shut and the drains open The pool pump may run to protect other equipment from freezing but no water should be able to enter the solar loop during this time 5 If water is observed coming out of the drains this indicates that the solar function is still enabled in the controller an isolation valve is open and or an isolation valve i...

Page 5: ...he solar pool heating collectors are exposed to sunlight and the pump s is running Remember the pump s should always run during daylight hours 3 After performing Steps 1 2 the diverter valve should have turned or remained in a state where water was being directed to the solar loop If the solar loop has a check valve with an integrated window the flapper should indicate if flow is present 4 If the ...

Page 6: ...sensors Make sure that all sensor wiring is undamaged and properly connected to the terminals in the controller If the error persists the temperature sensor may need to be replaced 2 Visually inspect the solar pool heating system to make sure no leaks are present If leaks are found or suspected please call your solar pool heating installer or pool service company for assistance MAINTENANCE AND TRO...

Page 7: ...800 79 SOLAR www umasolar com DISTRIBUTED BY ...