background image

 

2

Programming Guide

Things You Should Know

About This Programming Guide

This programming guide should be used in conjunction with the 

Magellan Reference & Installation Manual

 which can be downloaded 

from our website at 

www.paradox.ca

. Use this guide to record the settings programmed for this console.

Conventions

Installer Code (Default: 0000 / 000000)

The Installer code is used to enter programming mode (see 

Entering Programming Mode 

on page 3), which allows you to program all the 

features, options and commands of the Magellan console 

except

 user codes. The Installer code can be 4 or 6 digits in length (see section 

[090] option 

[1]

 on page 5) where each digit can be any value from 0 to 9. See section [181] on page 11 to change the default code.

Maintenance Code (Default: 1111 / 111111)

The Maintenance code is similar to the Installer code. It can be used to enter programming mode (see 

Entering Programming Mode 

on page 3), which allows you to program all the features, options and commands 

except

 for the Magellan console’s communication 

settings (sections [100] to [154]) as well as any user codes. The Maintenance code can be 4 or 6 digits in length (see section [090] 
option 

[1]

 on page 5) where each digit can be any value from 0 to 9. See section [182] on page 11 to change the default code.

Master Code (Default: 1234 / 123456)

With the System Master code a user can use any arming method and can program user codes. The System Master code can be 4 or 
6 digits in length (see section [090] option 

[1]

 on page 5), where each digit can be any digit from 0 to 9. The System Master code 

cannot be changed by the Installer or Maintenance code, but it can be reset to default. See section [200] on page 11 to reset to default.

Decimal and Hexadecimal Values

Figure 1: Decimal and Hexadecimal Values

This symbol designates a warning or important information.

This symbol designates a suggestion or reminder.

This symbol designates a reference to another section, manual or guide.

This symbol designates a feature that can also be programmed in the Installer menu which can be accessed by pressing 

[menu]

 and then entering your 

[

INSTALLER

 

CODE

]

. The icon will then be followed by the path or buttons that have to be 

pressed in order to access the feature once in the Installer menu. For example:

 = Once in the Installer menu, press the 

[4]

 key and then press the 

[6]

 key to access the desired feature.

Refer to the Installer Menu Overview on the back cover for more information on accessing and using the Installer menu.

J

[4] 

J

[6]

Decimal and 
Hexadecimal 
Values:

Keys 

[0]

 to 

[9]

 = 0 

to 9

Hexadecimal only 
values:
[1]

 = A

[2]

 = B

[3]

 = C

[4]

 = D

[5]

 = E

[6]

 = F

Summary of Contents for MG-6060

Page 1: ...Programmable Outputs PGMs 5 System Options 5 Communicator Settings 8 Report Codes 9 Remote Control Button Programming 10 System Settings 11 Wireless Programmable Output PGM Settings 12 Appendix 1 PGM...

Page 2: ...it can be any value from 0 to 9 See section 182 on page 11 to change the default code Master Code Default 1234 123456 With the System Master code a user can use any arming method and can program user...

Page 3: ...nLoad Software Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software Key 4 Call WinLoad Software Will dial the PC telephone number programmed...

Page 4: ...ell cut off time 004 mins 064 ____ ____ ____ x 15 minutes No movement time Disabled 065 ____ ____ ____ seconds minimum 10 seconds Intellizone delay 045 secs 066 ____ ____ ____ seconds Recent closing d...

Page 5: ...Silent or audible alarm Silent Audible 6 Panic 3 Silent or audible alarm Silent Audible 7 PGM1 used as MG 6060 only Direct output X10 output 7 8 PGM2 used as MG 6060 only Direct output X10 output 8 09...

Page 6: ...n trouble if detected on bypassed zone No Yes 095 Zone Options Bold Default setting Option OFF ON 1 Zone 15 is hardwire zone 1 Disabled Enabled 2 Zone 16 is hardwire zone 2 Disabled Enabled 3 EOL End...

Page 7: ...se Alarm Alarm Restore Report Codes 5 Call monitoring station telephone number 1 Disabled Enabled 6 Call monitoring station telephone number 2 Disabled Enabled 7 Call Pager telephone number Disabled E...

Page 8: ...eport format for monitoring station telephone number 2 107 ____ ____ ____ ____ Account number 108 ____ ____ ____ ____ Panel identifier for use with WinLoad software 109 ____ ____ ____ ____ Panel passw...

Page 9: ...____ ____ User Code 12 123 ____ ____ User Code 13 129 ____ ____ User Code 13 ____ ____ User Code 14 ____ ____ User Code 14 ____ ____ User Code 15 ____ ____ User Code 15 ____ ____ User Code 16 ____ __...

Page 10: ...Zone 6 ____ ____ Fail to comm ____ ____ Future use ____ ____ Installer logout ____ ____ Zone 7 ____ ____ TX low battery ____ ____ TX low battery ____ ____ Delinquency ____ ____ Zone 8 ____ ____ TX su...

Page 11: ...165 5 ______ ______ ______ ______ 173 13 ______ ______ ______ ______ 166 6 ______ ______ ______ ______ 174 14 ______ ______ ______ ______ 167 7 ______ ______ ______ ______ 175 15 ______ ______ ______...

Page 12: ...ent programmed 216 PGM4 Activation Event ____ ____ ____ ____ No event programmed 217 PGM4 Deactivation Event ____ ____ ____ ____ No event programmed Section 218 Wireless PGM Supervision Options Bold D...

Page 13: ...e center keypad 14 Utility Key 2 pressed keys 2 and 10 from the center keypad 15 Utility Key 3 pressed keys 3 and 11 from the center keypad 16 Utility Key 4 pressed keys 4 and 12 from the center keypa...

Page 14: ...gency 01 Panic medical this medical panic alarm is not UL approved 02 Panic fire 03 Recent closing 04 Global shutdown 05 Duress alarm User 16 99 Any special alarm event 25 Zone shutdown 01 to 16 Zone...

Page 15: ...d 43 PGM supervision lost 44 PGM supervision restored 45 PGM tampered 46 PGM tamper restored 01 to 04 PGM number 99 Any PGM number 47 Future use Future use 48 Fire delay started 01 to 16 Zone number 9...

Page 16: ...res into the AC terminals Back view of the Magellan console 12Vdc to 18Vdc 1A Insert the transformer s wires into the AC terminals DC Power Supply Backview of the Magellan console Insert the backup ba...

Page 17: ...and ahead of all other equipment attached to the same telephone line Proper installation is depicted in the diagram below If you have any questions concerning these instructions you should consult you...

Page 18: ...the Radio Antenna MG 6060 only Figure 9 Connecting the Radio Antenna Back view of the Magellan console If the radio reception is not very good connect the supplied radio antenna to the ANT terminal of...

Page 19: ...RJ 11 cable into the X10 plug of the console 2 Connect the other end of the inverted 4 pin RJ 11 cable into the X10 transmitter 3 Plug the X10 transmitter into a standard wall outlet 1 2 3 Do not con...

Page 20: ...n will begin downloading the data from the memory key Copy Data to Memory Key from Source Console To copy the contents of a console into the memory key 1 Remove power from the Magellan console AC and...

Page 21: ...e used to raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding when Magellan is being used Tabletop mounting may not be an approved ins...

Page 22: ...352 Telco 2 fault 5F 125 Duress Egress granted 12 System Troubles 300 and 310 353 Long range radio 60 Burglar Alarms 130 300 System trouble 39 354 Fail to communicate 61 130 Burglary 13 301 AC loss 3A...

Page 23: ...521 Bell 1 disabled AA 626 Time Date inaccurate D1 412 Success download access 84 522 Bell 2 disabled AB 627 Program mode entry D2 413 Unsuccessful access 85 523 Alarm relay disabled AC 628 Program mo...

Page 24: ...Open by user OR Disarm from Alarm Cancel alarm with User Code 1 4A6 Open by user OR Disarm from Alarm Cancel alarm with Keyswitch 1 4A6 Keyswitch Open OS Opening Keyswitch Auto Arming Cancellation 1 4...

Page 25: ...attery Trouble Module Auxiliary supply trouble 1 3AA System trouble YP Power Supply Trouble Bus fault restore 3 333 Expansion module failure restore ER Expansion Restoral Module tamper restore 3 145 E...

Page 26: ...e product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise from Seller offering to render or rendering technical ad...

Page 27: ......

Page 28: ...ring volume ring tone 9 demo mode on time on zone open remote button on exit delay when armed on entry delay on alarm house code Must enter the installer maintenance or user code to access Master Cod...

Reviews: