Use the following procedure to change the
dosing of the oil pump:
1.
Pull out the power plug of the machine.
2.
Put down the cable where you can see it.
3.
Open the spring-loaded lower protective flap
(11) downward.
4.
Using the combination screwdriver (B), turn
the fillister head screw (10)
counterclockwise
to loosen it.
Fig. 20: Opening the protective flap
5.
Open the cover and remove it.
Fig. 21: Removing the cover
6.
Using the combination screwdriver (B), turn
the hexagon socket screw (12)
counterclockwise
to loosen it.
7.
Remove the intermediate cover (13) and the
oil tank (14).