Upon receiving this command, the settings are stored in Flash memory and the unit will reboot once.
Example:
Set all alerts ON, periodic report OFF and name this profile FIRSTSET.
Command: SG211,0,1,0,1,0,0,0,0,0,0,1,0,1,0,1,0,0,FIRSTSET,
Response: @352238020015913,211,0,1,0,1,0,0,0,0,0,0,1,0,1,0,1,0,0,FIRSTSET,!
SG231: Query current interval, alert and threshold settings
Command: SG231
Response (SMS):
@<ID>,231,<INT_ON>,<ALT_ON>,<INT_OFF>,<ALT_OFF>,<TH_DC>,<TH_SP>,<TH_MI>,
<TH_BAT>,<PS>,<INT_MB>,<ALT_MB>,<INT_HB>,<ALT_PU>,<BZ>,<IG_TYPE>,<IDT>,<TOW>,<PF>!
–
Where <INT_ON> & <ALT_ON> are ignition ON reporting & alert settings
–
Where <INT_OFF> & <ALT_OFF> are ignition OFF reporting & alert settings
–
Where <TH_DC> is threshold of direction change
–
Where <TH_SP> is threshold of speed
–
Where <TH_MI> is threshold of mileage
–
Where <TH_BAT> is threshold of battery disconnected
–
Where <PS> is the power saving mode of GPS
–
Where <INT_MB> is the interval of battery disjunction
–
Where <ALT_MB> is the alert of battery disjunction
–
Where <INT_HB> is the interval of heartbeat location reporting
–
Where <ALT_PU> is to enable/disable Power Up alert
–
Where <BZ> is to enable/disable buzzer
–
Where <IG_TYPE> is the choice of ignition type
–
Where <IDT> is the threshold idle time
–
Where <TOW> is for controlling the detection of tow
–
Where <PF> is the profile name
Example:
Command: SG231
Response: @352238020015913,231,0,0,0,0,0,0,0,0,0,0,0,0,0,0,3,0,0,FGT!
Confidential, the whole document is the sole property of Maestro Wireless Solutions ltd.
3603-9, 36/F., 118 Connaught Road West, Sheung Wan, Hong Kong
35