Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in the U.S.A. 4/07 P/N 033-104 Rev. A
English
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz
300 W light / 1 A fan (3.5 A total)
Wall Control
MIR-LFQ35M: 120 V~ 60 Hz
3.5 A (one CM-L300FQ1M)
Accessory Control
MA-ALFQ35: 120 V~ 60 Hz
3.5 A
Infrared Wireless Transmitter
MIR-ITFS-LF:
3 V
0.15 W
Important Notes
Please read before installing.
1.
Caution:
To avoid overheating and possible damage to other equipment, do not use to
control receptacles, fluorescent or neon lighting fixtures, transformer-supplied appliances,
solid state fan motors,
or exhaust fans
. For exhaust fans use Lutron fully variable fan speed
controls.
2.
Install in accordance with all national and local electrical codes.
3.
When no “grounding means” exist within the wallbox then the NEC
®
2005, Article 404.9
allows a wall control without a grounding connection to be installed as a replacement, as
long as a plastic, noncombustible wallplate is used. For this type of installation, cap or
remove the green ground wire on the wall control and use an appropriate wallplate such as
Lutron’s
Claro
®
series wallplates.
4.
The
Maestro
®
dual fan/light control system consists of a Wall Control, a Canopy Module, and
up to two Accessory Controls. All must be installed correctly before attempting to control the
fan/light fixture. Do not attempt to mix Lutron controls with those from other manufacturers,
or mix Lutron controls not labeled for use together.
5.
This system is not compatible with fans having a control system built into the motor.
6.
Do not paint Wall Control, Canopy Module, or Accessory Control(s).
7.
Maestro
Controls are not compatible with standard 3-way/4-way switches.
8.
Accessory Controls (MA-ALFQ35) cannot be used individually and must be used in
conjunction with a
Maestro
Wall Control (MIR-LFQ35M) in a 3-way/4-way application.
9.
In any 3-way/4-way circuit use only one Wall Control (MIR-LFQ35M)with up to 2 Accessory
Controls (MA-ALFQ35).
10.
Do not use where total lamp wattage is less than 40 W or greater than 300 W.
11.
Operate between 32 °F (0 °C) and 104 °F (40 °C) room temperature. For indoor use only.
12.
Wall Control and Accessory Controls may feel warm to the touch during normal operation.
13.
Recommended wallbox depth is 2.5 in (64 mm) minimum.
14. Clean controls with a
soft damp cloth only
.
Do not use any chemical cleaners.
15.
This system cannot be used to change the direction of the fan. To change the fan direction,
stop the fan, and then change the position of the switch located on the body of the fan.
16.
To maximize light bulb life, use bulbs recommended for fan or “rough service” use.
17.
Do not use pull chains to operate fan/light after installing this system.
18.
Canopy Module must be installed within a fan canopy enclosure.
19.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
IR Quiet Fan Speed and Incandescent/
Halogen Dimmer Multi-Location System
Fan/Light
Warning: For use with one ceiling paddle fan and light only. Do not use with an
exhaust fan or more than one fan.
One ceiling fan only
No exhaust fans
P/N 033-104
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase.
For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage
pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY
IS LIMITED TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR
REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR
INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON
ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION,
DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last,
so the above limitations may not apply to you.
This product may be covered under the following U.S. patents: 4,835,343, 4,992,709, 5,017,837, 5,248,919, 5,399,940,
5,637,930, 5,798,581, 5,909,087, 6,169,377, 6,380,696, 7,142,932, 7,190,125; D525,948; and corresponding foreign patents.
U.S. and foreign patents pending. Lutron, Claro, Maestro, and Maestro IR are registered trademarks and FASS is a trademark of
Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.
© 2007 Lutron Electronics Co., Inc.
Operation
Light Level Tap Button
•
Tap once when lights are off -
Lights brighten smoothly to preset
intensity.
•
Tap once when lights are on -
Lights dim smoothly to off.
•
Tap twice quickly -
Lights brighten
rapidly to full intensity.
• Press and hold when lights are on
-
Activates delayed fade to off mode.
As the tap button is held, the LEDs
will begin to flash. The first flashing
LED represents a 10 second fade to
OFF. Each additional flashing LED
represents an additional 10 seconds
of delay before lights fade to OFF (up
to 60 seconds of delay).
Fan Speed Tap Button
•
Tap once when fan is off -
Fan
speed increases to preset level.
•
Tap once when fan is on -
Fan
speed slows to off.
•
Tap twice quickly -
Fan speed
increases to full speed.
Light Level LEDs
Indicate approximate light level
LEDs may not change with each
press
Press to increase light level
Press to decrease light level
Fan speed LEDs
Indicate exact fan speed
LEDs will change with each press
Press to increase fan speed
Press to decrease fan speed
(LEDs not available on Accessory Controls)
FASS
TM
- Front
Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, remove power by pulling the
FASS
switch out on the Control.
For any procedure other than routine bulb
replacement, power must be disconnected at the
main electrical panel.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all
inner side sections prior to wiring (see below). Using pliers, bend side sections up and down until
they break off. Repeat for each side section to be removed.
Note: Product does not require
derating when side sections are removed.
Breaking Side
Sections
?
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center
. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days):
1-800-523-9466
Other countries 8am – 8pm ET:
+1-610-282-3800
Fax +1-610-282-6311
http://www.lutron.com
Inside sections are
removed from each
control
Side sections are
removed from both
sides of middle control
Do not remove
outside
sections.
Lutron Technical Support Center
1-800-523-9466 24 hrs / 7 days www.lutron.com
ON
OFF
ON
OFF
ON
OFF
Turn OFF power.
•
Turn power OFF at circuit breaker (or remove fuse).
Canopy Module Installation
Set fan speed and lights.
•
Set fan to highest speed and turn lights on using pull chains.
•
If two switches control the fan and light separately, note which controls the light.
Install fan.
•
Install fan according to manufacturer's instructions and check for proper operation.
3
3
2
2
1
1
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the supplied wire
connectors (see wire connector bag).
Note:
All wire connectors provided are suitable for
copper wire only.
For
aluminum wire, consult an electrician.
Wire Connectors:
Use to join 14 AWG or 12 AWG ground wire to 18 AWG Wall Control
ground wire, and to join 18 AWG Canopy Module wire to 12, 14, 16
or 18 AWG wire.
Twist wire
connector
tight.
Connect Canopy Module.
• If you have questions about wiring, call the
Lutron Technical Support Center
at
1-800-523-9466.
Fan
Canopy
Module
Switched Live
Black
White
Yellow
Red
Neutral
Light
Canopy
Module Wire:
White
Black
Yellow
Red
Connects to:
Neutral wires in the
junction box and to fan
Switched Live wire from
Wall Control
Fan
Light
5
5
To junction box
To fixture
Wiring the Canopy Module (CM-L300FQ1):
Use wire connectors to join wires as indicated below
and in the wiring diagram, and to
cap any unused
wires
.
Troubleshooting
Symptom
Light or fan does not turn ON or no LEDs
turn ON.
Upper LEDs on Wall Control cycle rapidly
and bottom LED is ON.
Upper LEDs on Wall Control cycle rapidly
and second lowest LED is ON.
Fan vibrates or wobbles.
Light dims in large steps and fan is noisy or
does not spin at correct speed.
Light button controls fan and vice-versa.
Fan speeds too slow.
Wall Control LEDs respond as expected but
fan and/or light does not respond properly.
Light or fan does not respond to infrared
wireless transmitter.
Possible Cause
•Front Accessible Service Switch (
FASS
) on
control is pulled out to the OFF position.
•Manual switch on fan is off (ex: pull chain).
•Light bulb(s) burned out.
•Breaker is OFF or tripped (or fuse blown).
•Fan direction switch is between forward and
reverse.
•Wiring error, call
Lutron Technical Support
Center
at 1-800-523-9466.
•Unit is not activated properly. Activate system
as described in Step 15.
•Wiring error, call
Lutron Technical Support
Center
at 1-800-523-9466.
•Communication error. Check wiring; if error
continues, call
Lutron Technical Support
Center
at 1-800-523-9466.
•Fan blades not properly balanced. See fan
manufacturer's instructions.
•Fan and light control wires on Canopy Module
are reversed.
•Fan and light control wires on Canopy Module
are reversed.
•Fan pull chain not set to high.
•Fan and/or light pull chains not set to high/on.
•Wiring error, call
Lutron Technical Support
Center
at 1-800-523-9466.
•Transmitter batteries installed incorrectly.
•Transmitter batteries are dead.
•Transmitter not aimed directly at wall control.
•Transmitter outside operating range.
•Wall control has already received and
responded to command.
Fan
Light
Neutral
If the fan and light do not have separate wires, the fixture may have a control
system built into the motor and cannot be used with this product.
Typical Wire Colors
Black
Black with White stripe or Blue
White
Disconnect fan.
• Remove canopy enclosure from ceiling fan mounting bracket.
• If separate wires from the junction box power the fan and light, tag the wire connected to the light
wire. In Step 5, connect this wire to the black Canopy Module wire.
• Leave any green ground wires connected as directed in fan manufacturer's instructions.
• Disconnect fan from remaining wiring in the ceiling.
4
4
To junction box
To junction box
Flush Mount Bracket
Down Rod Bracket
Mounting
bracket
Canopy
enclosure
Multiple Gang Application
Maestro IR
®
fan controls may be ganged together with Maestro IR
®
dimmers, but
should not be ganged with other
Maestro IR
®
fan or fan/light controls. If ganged with
Maestro IR
®
dimmers,
button presses on a Dimmer IR transmitter will affect all
light controls; button presses on a Fan IR transmitter will affect only the fan
control.
• Pressing the ON FULL button will cause each control to fade to its highest level,
regardless of whether some are on and some are off.
• Pressing the OFF button will cause all controls to turn off.
• Pressing the RAISE or LOWER buttons will change the control level on all units at the
same rate until the button is released or until the controls have reached their
maximum or minimum level. If any units are off when the RAISE button is pressed,
they will turn on at the minimum control level.
• To save your favorite control level, adjust all the controls to the desired level, then
press and hold the FAVORITE button for about 3 seconds until the LEDs begin to
flash. Once your favorite level is set, pressing the FAVORITE button will cause each
control to return to your programmed favorite level.
Infrared Wireless Transmitter Operation
Point the transmitter at the
Maestro IR
®
Wall Control(s), then use the buttons as outlined below.
LIGHT ON FULL:
Tap once: lights brighten
smoothly to full intensity.
FAN ON FULL:
Fan speed increases to full
speed.
LIGHT OFF:
Tap once: 3 second fade to off
Press and hold: 10–60 second
delayed fade to off.
FAN OFF:
Fan speed slows to off.
LIGHT RAISE:
Press to increase light level
LIGHT LOWER:
Press to decrease light level
LIGHT FAVORITE LEVEL:
Tap once to recall your favorite light
level.
To store your favorite speed, press
and hold for about 3 seconds until
the wall control LED begins to flash.
(“Off” is a valid preset level.)
FAN RAISE:
Press to increase fan speed
FAN LOWER:
Press to reduce fan speed
IR
®
This transmitter is compatible with
most learning remote controls.
Please see the learning remote
control manufacturer’s instructions
for programming information.
FAN FAVORITE LEVEL:
Tap once to recall your favorite
fan speed.
To store your favorite level,
press and hold for about 3
seconds until the wall control
LED begins to flash. (“Off” is a
valid preset level.)