background image

Lutron Technical Support Center     1-800-523-9466     24 hrs / 7 days     www.lutron.com

Cable tie

6b - Flush Mount Bracket

• Do not install Canopy Module in ceiling.
• Attach Canopy Module to bracket with a cable tie.
• Ensure cable tie does not come in contact with moving motor parts.
• Install cable tie through notches on Canopy Module. Pull tight and clip excess.

To junction box

6a - Down Rod Bracket

• Do not install Canopy Module in ceiling.
• Slide Canopy Module into the ceiling fan mounting bracket.

To junction box

Remove original wallplate and switch.

• Remove the wallplate and switch mounting screws.
• Carefully remove switches from wall 

(do not remove wires)

.

Attach canopy.

Control Installation

7

7

8

8

7b - Flush Mount Bracket

• Check all wire connections.
• Tuck the wires into the junction box and/or bracket.
• Ensure wires and/or wire connectors do not come in contact with moving motor parts.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.

To junction box

To junction box

7a - Down Rod Bracket

• Check all wire connections.
• Tuck the wires into the junction box and/or canopy enclosure.
• Attach the canopy enclosure to the fan mounting bracket, taking care not to pinch any wires.

Danger:

Verify power to

each switch is OFF
before proceeding.

Important Note:

Your wall switch may have two wires attached to the same screw (see illustrations below for examples). Tape
these two wires together before disconnecting. When wiring, connect wires to new Controls the same way they
were connected to the switch.

Identify switch wires.

• If two switches control the fan and light separately, tag the wires connected to the light switch. In Step 12,

connect these wires to the Wall Control.

1

10

0

One wire in
the push-in
terminal and
one to the
screw.

One
continuous
wire to the
screw.

Disconnect switch wires.

Connect Control(s).

• For installations involving more than one control in a wallbox, refer to Multigang Installations

before beginning.

• Only one Wall Control (MIR-LFQ35M) can be used with up to 2 Accessory Controls (MA-ALFQ35).

Ground

Green wire

Black
screw

Wall Control

Brass
screws

Important Wiring Information

Push-in Terminals: Insert wires fully.
NOTE:

Push-in terminals are for use with 14 AWG 

solid copper wire only. DO NOT

use stranded or twisted wire.

Screw Terminals: Tighten securely.

Screw terminals are for use with 12 or 14 AWG 

solid copper wire only. DO NOT

use stranded or twisted wire.

Trim or strip wallbox wires to the length indicated by the strip gauge on the back of the control 

OR

1

12

2

1

11

1

Screw Terminals: 
Turn screws to loosen.

Push-in Terminals:
Insert screwdriver.
Pull wire out.

Looped Wire:
Turn screw to loosen.

Wiring the Wall Control (MIR-LFQ35M):

• Use wire connectors to connect the 

green 

ground

wire on the Wall Control to the 

bare copper

or 

green

ground wire in the wallbox (see 4-Important Wiring
Information).

• Connect either of the wires removed from the switch

to the 

black

screw terminal on the Wall Control.

• Connect the remaining wire removed from the switch

to one of the 

brass

screw terminals on the Wall

Control.

• Tighten the remaining 

brass

screw terminal on the

Wall Control. It is not used in a single-pole circuit.

Cap any unused wires.

Mount Control(s) to wallbox.

• Form wires carefully into the wallbox, mount and align the Control(s).
• Install wallplate(s).

Caution:

Do not

overtighten
mounting screws.

1

13

3

Align control and
tighten screws.

Start screws.

Insert Canopy Module.

6

6

1

15

5

1

16

6

ON

OFF

ON

OFF

ON

OFF

Turn ON power.

• Do not turn on power until Wall Control, Accessory Control(s) and Canopy Module have been

installed and wired.

• Turn power ON at circuit breaker (or replace fuse).

Recommended - Disconnect pull chains.

• Disconnect pull chain extensions to prevent light and fan speeds from being adjusted at the fan.

Activate system.

• Pull out the Front Accessible Service Switch (

FASS) at the bottom

of the Wall Control, wait 10 seconds, then push it back in.

• The LEDs will cycle for up to 30 seconds.
• If installing more than one Wall Control/Canopy Module system,

activate one at a time with 

FASS pushed in on all other systems.

• Accessory Controls do not require activation.

1

14

4

Identify the circuit type.

One switch controlling a fan/light fixture.

This switch will be a single-pole. The switch will have
insulated wires connected to two screws of the same
color plus a green ground screw.

Ground
(Bare Copper or
Green Wire)

Two switches controlling a fan/light fixture.

Both switches will be 3-way. Each switch will have
insulated wires connected to three screws plus a green
ground screw. One of these wires is connected to a screw
of a different color (not green) or labeled COMMON.

TAG

this wire on both switches to identify when wiring.

Tagged wire

Different colored
screw (Common)

Ground
(Bare Copper or
Green Wire)

Three switches controlling a fan/light fixture.

Two switches will be 3-way and one will be a 4-way.

TAG

the two 3-way switches as in the Two-Location diagram
above. The 4-way switch will have insulated wires
connected to four screws plus a green ground screw.

TAG

two insulated wires which are connected to same colored
screws.

Tagged wires

Note: Screw
placement may
be different on
your switch.

Same colored
screw (or
marked IN or
OUT)

Ground
(Bare Copper or
Green Wire)

9c - Three-Location control

9b - Two-Location control

9a - Single-Location control

12a - Single-Location control

12b - Two-Location control

One location will be replaced with a Wall Control (MIR-LFQ35M) and the other with an Accessory Control
(MA-ALFQ35).

Ground

Tag

Green wire

Wiring the Wall Control and Accessory Control:

• Use wire connectors to connect the 

green 

ground

wire on the Control to the 

bare copper

or 

green

ground wire in the wallbox (see 4-Important Wiring
Information).

• Connect the tagged wire removed from the switch to

the 

black

screw terminal on the Control.

• Connect one of the remaining wires removed from the

switch to one of the 

brass

screw terminals on the

Control.

• Connect the remaining wire removed from the switch

to the remaining 

brass

screw terminal on the Control.

• Cap any unused wires.

Live

120 V~

60 Hz

Neutral

Canopy Module

and Fan/Light

Fixture

Black

Green

Green

Ground

Ground

Wallbox

Wall Control or 

Accessory Control

Wall Control or 

Accessory Control

Wallbox

Wallbox

Reference Wiring Diagram

12c - Three-Location control

One location will be replaced with a Wall Control (MIR-LFQ35M) and the other two with Accessory Controls
(MA-ALFQ35).

Replace the 4-way switch

Note: 

4-way switch may be replaced with either a

Wall Control or an Accessory Control

• Use wire connectors to connect the 

green 

ground

wire on the Control to the 

bare copper

or 

green

ground wire in the wallbox (see 4-Important Wiring
Information).

• Connect both of the tagged wires removed from the

4-way switch to the 

black

screw terminal on the

Control (one wire to the screw and the other to the
push-in terminal).

• Connect one of the remaining wires removed from

the switch to one of the 

brass

screw terminals on

the Control.

• Connect the remaining wire removed from the

switch to the remaining 

brass

screw terminal on the

Control.

• Cap any unused wires.

Replace the two 3-way switches

Follow Step 12b - Two-Location control.

Ground

Tagged wires

Green wire

Live

120 V~

60 Hz

Neutral

Canopy Module

and Fan/Light

Fixture

Brass

Brass

Black

Black

Green

Green

Ground

Ground

Wallbox

Wall Control or 

Accessory Control

Wall Control or 

Accessory Control

Wall Control or 

Accessory Control

Wallbox

Green

Ground

Wallbox

Reference Wiring Diagram

9

9

Wall Control and

Accessory Control

Wall Control or

Accessory Control

Brass

Brass

Brass

Black

Brass

Brass

Brass

Black

Black

Brass

Brass

Black
screw

Brass
screws

Black
screw

Brass
screws

Notch

Note: Screw
placement may
be different on
your switch.

Warning:

Fan will return to

full speed when power is
restored. Clean up any tools
or ladders near the fan first.

Live

Switched

Live

120 V~

60 Hz

Neutral

Canopy
Module 

Green

Ground

Yellow (Fan)

Brass

Ceiling Fan
and Light

Black

Black

White

Brass

Red (Light)

Reference Wiring Diagram

Junction box and Canopy

Wall Control

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

Reviews: