Beware that the interface works with electrical power. Only use the
device in dry environments (indoor use). The IP Rating of the device
is IP20. Do not use the interface in humid environments and avoid

contact with water or any other liquids. Turn off the power if you are not using
the device for a long time.
Avoid unwanted voltage on the cables at all times. Do not remove any parts from
the unit or connect to an ungrounded circuit. Do not connect the unit to LEDs
that are switched on. Only connect the unit to LEDs and controllers that are
initially powered off.
There are no user-reparable parts inside or outside the interface. Repair service
lies only within the responsibilities of the manufacturer. If the interface appears
to be defective, please contact your dealer. After expiration of the warranty
period, you may contact your supplier or the manufacturer to have the unit
repaired against payment of an individual service fee if possible.
The interface has several ports and slots. Only connect or insert devices, cables,
and connectors to the individual ports and slots using connectors of the same type
as the port. Do not use inapplicable equipment. This device should be used by
professionals. The device is not designed to be operated by non-professionals or
children.

Recommendation: DIN-Rail Power Supply 12 V (MEAN WELL HDR-15-12,
DC Output, 12 V, 1.25 A, 15 W, 1 SU, DIN Rail) / Order Number: IA-HW-001027.

Safety Instructions

Please follow the instructions below to avoid mishandling, damage to the
device, or personal injury:

THE DEVICE WORKS WITH LOW VOLTAGE (DC 5 V – 24 V).
DO NOT USE ANY OTHER VOLTAGE!

External USB power supplies: Using non-permissable units
poses risk of fire. 5.5 V

500 mA max. output is allowed.

Any connected external power supply needs to be fused
according to its output and/or short-circuit proof.

In order to cut off the supply of power completely, you need to
disconnect any external power-supply unit as well as USB.

Summary of Contents for Nebula

Page 1: ...NEBULA T echnical Manual Quick Start Guide...

Page 2: ...an Hertel Sebastian Pinzer Sebastian Wissmann Trademark Credits Microsoft and Windows are U S registered trademarks of Microsoft Corporation Art Net DesignedbyandCopyrightArtisticLicenceHoldingsLtd Al...

Page 3: ...damages as well as consequential damages are direct or indirect whether they are special damages or others nor if the damage is caused by the owner of the warranty or a third person Limited Warranty...

Page 4: ...er to have the unit repaired against payment of an individual service fee if possible The interface has several ports and slots Only connect or insert devices cables andconnectorstotheindividualportsa...

Page 5: ...I II 3 4 incl ArtSync Streaming ACN sACN ANSI E1 31 Acts on commands and replies to requests with its own status and sensor data via ArtRdm RDM Responder 8x 512 channels SPI TTL Maximum output per por...

Page 6: ...h MADRIX NEBULA but only required if you would like to send or receive data over USB For more information about MADRIX 5 including its minimum system requirements and supported operating systems visit...

Page 7: ...or Port 1 8 Status LED for Port 2 9 Port 1 10 Reset button 11 DIN rail unlocking clip 12 Port 2 2x Mounting Brackets Put each bracket in the pre drilled holes on the device s left and right side Safel...

Page 8: ...terminal into the device The screws must face upwards Step 4 Connect to USB or to Ethernet network for data as required Step 5 Do not switch on your supply of power until all required power cables and...

Page 9: ...ATA Connection possible for CLOCK if needed Connection required for V Represents single LEDs or multiple LED stripes LED strips LED tape up to the maximum possible amount per port Represents as many p...

Page 10: ...AandsuppliedseparatelytotheLEDs asrequired TheLEDs are connected only to Port 1 or only to Port 2 via GROUND DATA and possibly CLOCK but not via V Network Data Power Supply Variation C1 Port 1 or 2 De...

Page 11: ...s supplied to both LEDs as required LEDs are connected to both ports via GROUND DATA possibly CLOCK but only once via V The power supply is connected between LEDs and NEBULA due to the expected voltag...

Page 12: ...at the end of the tape for LEDs that use 9 V Power USB Data Variation X1 Port 1 or 2 Description Power is supplied only once It is supplied to NEBULA with 12 A max and routed through to the LEDs whic...

Page 13: ...max and routed through to all LEDs which are connected to both ports via GROUND DATA possibly CLOCK and V with 6 A max load for each port Power Supply USB Data Variation Z Description Power is supplie...

Page 14: ...Using The MADRIX HARDWARE MANAGER Software Step 1 Connect devices to your computer over USB or network but not both Step 2 Make sure to stop sending control data to the devices Step 3 Start the MADRI...

Page 15: ...off No data is sent No data is sent Blinking green Sending data to Port 1 The output port works Sending data to Port 2 The output port works STATUS STATUS LEDS ETHERNET PORTS Green off 10 MBit s conne...

Page 16: ...ft the device from the rail Using The MADRIX 5 Software You can mainly use 3 operating modes together with the MADRIX 5 Software Output Via Art Net Output Via Streaming ACN Output Via USB First make s...

Page 17: ...t the new firmware from the list for your devices For more information see the MADRIX HARDWARE MANAGER User Manual Further Information Digital documentation files including this technical manual the g...

Page 18: ...work or use the built in daisy chain support see p 5 Where do I activate the ArtSync sync mode IntheMADRIX 5Software itcanbeactivatedunder Preferences Device Manager tab Art Net ArtSync Where can I fi...

Page 19: ...in English and German Entwickelt und hergestellt in Deutschland Impressum Gesch ftsf hrer Christian Hertel Sebastian Pinzer Sebastian Wissmann Amtsgericht Dresden HR B 29795 WEEE Reg Nr DE 26695213 US...

Page 20: ...oder spezielle Sch den handelt und ob diese vom Besitzer oder einer dritten Person verursacht wurden Garantie Der K ufer dieses Produktes erh lt f nf Jahre eingeschr nkte Herstellergarantie auf das Pr...

Page 21: ...gefragt werden Verbinden Sie nur Ger te Kabel Anschl sse o die dem Typ des jeweiligen Anschlusses am Ger t entsprechen Verbinden und benutzen Sie keine Ger te mit falschen Anschl ssen Das Ger t sollte...

Page 22: ...et I II 3 4 inkl ArtSync Streaming ACN sACN ANSI E1 31 F hrt Kommandos aus und reagiert auf Anfragen mit eigenen Status und Sensordaten ber ArtRdm RDM Responder 8x 512 Kan le SPI max Ausgabe pro Ansch...

Page 23: ...g von MADRIX NEBULA empfohlen aber nur f r das Senden von Daten ber USB zwingend ben tigt WeitereInformationen berMADRIX 5 inklusivemin Systemanforderungenund unterst tzte Betriebssysteme stehen zur V...

Page 24: ...f r Anschluss 1 8 Status LED f r Anschluss 2 9 Anschluss 1 Port 1 10 Reset Taste 11 Hutschienen Entriegelung 12 Anschluss 2 Port 2 Hinweis Netzwerkkabel Stromkabel oder LEDs sind nicht im Paket entha...

Page 25: ...nstecken Die Schrauben der Klemme m ssen dabei nach oben zeigen Schritt 4 Datenverbindung wie ben tigt ber USB oder Netzwerk herstellen Schritt 5 Die Spannungsversorgung erst herstellen wenn alle Stro...

Page 26: ...Bedarf m glich f r TAKT Verbindung erforderlich f r V Repr sentiert einzelne oder mehrere LED Ketten bis zur maximalen Anzahl an LEDs je Anschluss Repr sentiert die Anzahl an Spannungsversorgungen we...

Page 27: ...Die Spannungsversorgung wird separat f r NEBULA und die LEDs wie ben tigt bereitgestellt Die LEDs sind entweder an Anschluss 1 oder 2 angeschlossen ber MASSE DATEN und TAKT bei Bedarf aber nicht ber...

Page 28: ...wird f r alle LEDs wie ben tigt bereitgestellt LEDs sind an beiden Anschl ssen verbunden ber MASSE DATEN und TAKT bei Bedarf aber nur einmal ber V Spannungsversorgung zwischen LEDs und NEBULA aufgrun...

Page 29: ...sversorgung wird separat f r NEBULA ber USB und die LEDs wie ben tigt bereitgestellt Die LEDs sind mit NEBULA verbunden ber MASSE DATEN und TAKT bei Bedarf aber nicht ber V Spannungsversorg Daten ber...

Page 30: ...D Kette f LEDs 9 V Spannungsversorgung Daten und Strom ber USB Variante Y2 Beschreibung Die Spannungsversorgung wird separat f r NEBULA ber USB und die LEDs wie ben tigt bereitgestellt LEDs sind an be...

Page 31: ...ritt 1 VerbindenSieGer temitd PC berUSBoderNetzwerk nichtbeides Schritt 2 Stellen Sie den sonstigen Datenverkehr zu den Ger ten ein Schritt 3 Starten Sie die Software Schritt 4 Navigieren Sie zu Devic...

Page 32: ...t hat keinen Strom Permanent gr n Spannungsversorgung liegt an Das Ger t hat Strom Gr n blinkend Bootloader aktiviert Zur cksetzen Firmware einspielen STATUS STATUS LED USB Ausgeschaltet USB nicht ang...

Page 33: ...Ger te konfiguriert und aktiviert werden Systemeinstellungen Ger teverwaltung DMX Ger te Weitere Informationen finden Sie im Benutzerhandbuch von MADRIX 5 Montage auf Hutschienen Montage Links abgebil...

Page 34: ...Dokumentation inklusive dieses Technische Handbuch das allgemeine Benutzerhandbuch sowie das Datenblatt stehen online in digitaler Form zur Verf gung auf help madrix com Diese werden auch automatisch...

Page 35: ...ten mit einem Switch 1 GBit s als Netzwerk verbinden oder die eingebaute Netzwerkreihenschaltung nutzen siehe S 5 Wo kann ich den Modus zur Synchronisation ArtSync einstellen Dieser kann in der MADRIX...

Page 36: ...www madrix com...