MadMan CLD2 User Manual Download Page 4

 
 
 
 
 

 

 CLD Users Manual                       

 

 

 

 

 

Page 4 

2 Specifications

 

 
Operating Temperature Range

 

-10ºC to 60ºC (14ºF to 122ºF)

 

Storage Temperature Range

 

-20ºC to 80ºC (-4ºF to 176ºF)

 

Humidity 

<85% non-condensing

 

Power Supply

 

8 to 30VDC Linear power supply with built in 33V over voltage and reverse 
voltage protection

 

Current Consumption

 

approx. 10mA (depending on alarm mode)

 

Visual indication

 

Bi-Color LED (Red/Green)

 

Audio Indication

 

Piezo element

 

Probe excitation

 

2.5KHz AC signal

 

Alarm Contact 

Transistor open collector, Max current = 50mA

 

Non-volatile memory storage

 

1000000 write cycles

 

 

3 Warranty

 

 

This product carries a warranty for a period of one year from date of purchase against faulty workmanship or defective 
materials, provided there is no evidence of misuse or evidence that the unit has been mishandled. Warranty is limited to 
the replacement of faulty components and includes the cost of labour. Shipping costs are for the account of the 
purchaser.  
 
 
 
 
 
 
 
 

4 Disclaimer

 

 
 
Operation of this instrument is the sole responsibility of the purchaser of the unit. The user must make themselves familiar 
with the operation of this instrument and the effect of any possible failure or malfunction.  
 

 
 
 

Note: 

Product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired 

electrical supplies and or sensors, and damage caused by inductive loads or moisture. 

 

The manufacturer reserves the right to alter any specification without notice

 