1 Installation
Connect the CLD2 unit as indicated in the following diagram.
Mounting the Level Sensor:
There are two basic methods of sensing the coolant level, either with the included self tapping screws
screwed into the coolant bottle or by using a separately supplied level sensing plug.
Self Tapping Screws Option:
Level Sensing Plugs:
These plugs are available in different thread
sizes to suit coolant plugs or bleed screws
originally fitted to engines.
1/2BSP, M6x1, M10x1, M12x14tpi, others
on request.
Currently to suit Land Rover Tdi, Td5, V8
and TdV6
Mounting of the Switch and Led:
The LED holder requires a neat 8mm hole in a panel. Push the LED holder in from the front. Look at the LED, it has 3
legs, the shorter of the two outer legs corresponds to a tiny flat side on the rim of the LED, This pin must line up with the
GREEN wire on the 3way connector.
Push the white 3 way connector onto the LED legs carefully and push the LED into the LED holder from the back of the
panel.
The switch requires a 7mm hole, inserted and screwed in from the back of the panel. Push the button onto the switch
spindle until it clicks on.
Place -25mm below the
normal water level or on the
recommended minimum mark.
Screws must be horizontal and
25mm apart.
Drill 1.5 to 2mm holes for the
4.2mm Screws