6. Technical parameter
Model
SUME60
/240MM
SUME80
/240MM
SUME110/
240MM
SUME130/
240MM
SUME160/
240MM
SUME200/
240MM
SUME250/
240MM
PERFORMANCE CONDITION: Air 27°C/ Water 27°C/ Humid. 80%
Heating capacity (kW)
6.3
8.0
9.5
13.0
16.0
20.0
25.0
COP Range
5.5~10.1
5.2~10.1
5.4~10.5
5.6~10.8
5.8~10.9
5.7~10.5
5.8~11
PERFORMANCE CONDITION: Air 15°C/ Water 26°C/ Humid. 70%
Heating capacity (kW)
4.4
6.0
7.0
9.5
11.2
13.5
17.0
COP Range
4.1~6.3
4.0~6.2
4.2~6.5
4.0~6.2
4.3~6.6
4.2~6.5
4.0~6.6
TECHNICAL SPECIFICATIONS
Advised pool volume (m
3
) *
15~25
20~40
25~50
35~65
40~75
50~90
60~110
Operating air temperature
(
℃
)
0
℃
~43
℃
Rated input power (kW)
0.21~1.07
0.29~1.50
0.32~1.67
0.45~2.38
0.50~2.60
0.62~3.21
0.76~4.25
Rated input current (A)
0.94~4.88
1.32~6.82
1.47~7.58
2.05~10.80
2.27~11.84
2.80~14.61
3.44~19.32
Maximum input current (A)
6.5
8
9.5
12.5
17
19.5
20
Sound level at 10m dB(A)
19.8~31.2
21.8~32.1
21.6~33.5
23.9~34
26.2~37.3
26.3~38.1
26.9~38.7
Advised water flux (m³/h)
2~4
2~4
3~5
4~6
6~8
7~10
10~12
Water connection (mm)
40
Remarks:
This heat pump is able to perform normal within air temp 0
℃
~
+43
℃
, efficiency will not be guaranteed
out of this range. Please take into consideration that the pool heater performance and parameters are
different under various conditions.
Related parameters are subject to adjustment periodically for technical improvement without further
notice. For up to date details please refer to nameplate on the heat pump.
Summary of Contents for Summer Eco SUME100/240MM