3. Wiring
a. Connect to appropriate power supply, the voltage should comply with the rated voltage of the
products.
b. The machine
must
be earthed
c. Wiring must be handled by a professional technician according to the circuit diagram.
d. Set earth leakage protector according to local code for wiring (leakage operating current ≤ 30mA).
e. The layout of power cable and signal cable should be orderly and not affecting each other.
4. Electric wiring Diagram
For power supply: 230V/50Hz
5. Reference for protecting devices and cable specification
※
Above data is subject to modification without notice.
Note:
The above data is associated to power cables less than 10m. If power cable is longer than 10m,
the wire diameter must be increased in accordance with current regulations. The signal cable can
be extended to a maximum of 50m.
MODEL
SUME60/
240MM
SUME80/
240MM
SUME110
/240MM
SUME13
0/240MM
SUME16
0/240MM
SUME20
0/240MM
SUME25
0/240MM
Breaker
Rated Current A
8
9.5
11.5
15
20.5
23.5
24
Rated Residual
Action Current mA
30
30
30
30
30
30
30
Power Supply
230V 50Hz
Earth
Distribution Box (Not Supplied)
Power Cable
Swimming Pool Heat Pump Wiring Board
Fuse
Breaker
Summary of Contents for Summer Eco SUME100/240MM