background image

Page 16

MadgeTech  PR2000

5.5.ii.c   Power Status

 

Selecting “MORE” by either pressing the F4 key or the OK key while 

  

viewing the Display Update Mode screen brings up the Power Status 

 

screen. On this screen the battery type is displayed and should be 

 

changed by the user based on whether a Lithium or Alkaline battery 

 

is used in the PR2000. This can be changed by first pressing the F1  

 

button to highlight the type parameter configuration tab. Once the  

 

tab is highlighted, the battery type can be changed by either  

 

pressing the F1 key repeatedly or by using the UP and DOWN 

 

arrows to select the correct battery type. The percent battery power 

 

remaining, external power presence, battery voltage and external 

 

power voltage are also displayed on the Power Status screen.

 

5.5.iii  Device Information

The F3 key in the Setup Menu displays the Device Information screens. Here  
device identification information can be found including serial number, product 
ID, revision, and subtype. Calibration parameters are also found under device 
information including the date the device was last calibrated and when it will  
be due for calibration again. Firmware details are also found here. 

   

 

5.5.iii.a  Device Range (Minimum)

 

The Minimum Device Range screen can be accessed by pressing the  

 

F1 key while viewing the Device Information screen.  This display  

 

indicates the minimum values which the PR2000 is capable of  

 

detecting and logging.  Values on this screen cannot be modified. 

 

 
 

5.5.iii.b  Device Range (Maximum)

 

The Maximum Device Range screen can be accessed by pressing the  

 

F2 key while viewing the Minimum Device Range screen.  This display  

 

indicates the maximum values which the PR2000 is capable of 

 

detecting and logging.  Values on this screen cannot be modified.

 

 
 

5.5.iii.c  Calibration Parameters

 

Pressing F3 while in the Maximum or Minimum Device Range  

 

screens will display the device calibration parameters. This screen  

 

displays information indicating the most recent calibration date as  

 

well as the date the next calibration will be due. 

   
It is important to keep your device properly calibrated to  
ensure accurate readings.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for PR2000

Page 1: ...PR2000 Data Logger Manual Red 485 Dark Blue Pantone 289 Light Blue 58 of Pantone 289 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Page 2: ...display units 9 4 2 Changing the number type and size of channels viewed 9 4 3 Checking the memory status 10 4 4 Checking power status 10 4 5 Changing the Contrast 10 Section 5 PR2000 Function Referen...

Page 3: ...tion Screens Maximum Device Range 27 6 19 Device Information Screens Device Version 27 6 20 Device Information Screens Firmware Version 28 6 21 Calibration Information Screens Calibration Date 28 6 22...

Page 4: ...ons Pressure Range 0 to 30 100 300 and 500 PSIA G 0 to 1000 and 5000PSIA Resolution 0 002 0 005 0 02 0 05PSIA G Calibrated Accuracy 2 FSR 0 25 25 C typical Dot Matrix LCD Dimensions 2 5 x 1 375 63mm x...

Page 5: ...een use 360 days with display off Data Format Date and time stamped PSI inHg mmHg bar atm Torr Pa kPa MPa Time Accuracy 1 minute month at 20 to 30 C Computer Interface USB interface cable required 115...

Page 6: ...atteries Except as to title this is our only warranty for the products MadgeTech Inc expressly disclaims all other warranties guarantees or remedies whether expressed or implied or statutory including...

Page 7: ...view LED Indicators LCD Screen Pressure Sensor Power Jack Communication Jack Up Key Okay Key Down Key Cancel Key Function Keys Black anodized aluminum enclosure www GlobalTestSupply com Find Quality P...

Page 8: ...the battery should be replaced 3 2 Memory Status Memory Memory Empty Full The memory status icons indicate the amount of memory left for data storage If the PR2000 is in wraparound mode the memory sta...

Page 9: ...n The wait icon indicates that the device is busy 3 6 Stop Icon Indicates that the PR2000 is not currently taking readings 3 7 External Power Icon Indicates that the PR2000 is powered by an external s...

Page 10: ...ed on a smaller or larger scale To change the number and type of displayed channels From the Main Screen press the F4 key to enter the Setup Menu and from this menu press the F1 key to enter the Displ...

Page 11: ...e can also be viewed From the Main Screen press F4 to view the Device Configuration Menu F2 to access the power options then F4 twice to view the Power Status screen including battery power percent re...

Page 12: ...ewed by pressing the F2 and F3 keys respec tively 5 2 i Run Parameters The Run Parameters screen displays important information regarding the device s current recording session These parameters includ...

Page 13: ...ewing statistics by type The PR2000 s Statistics Menu also provides the option to view statistics by type This can be done by pressing F2 while in the Statistics Menu Here the function keys F1 F2 and...

Page 14: ...ry power remaining and the presence of external power and options regarding the LCD and the backlight can be modified The setup menu is also the place to find basic information regard ing device ident...

Page 15: ...guration parameter by pressing the F1 key This action will highlight the function tab corresponding to the F1 key Once this tab is highlighted the contrast can be increased or decreased using the UP a...

Page 16: ...per left corner of the PR2000 can be regulated by first pressing the F3 key to highlight the LED parameter configuration tab Once the tab is highlighted the option can be changed by pressing the F3 ke...

Page 17: ...are also found under device information including the date the device was last calibrated and when it will be due for calibration again Firmware details are also found here 5 5 iii a Device Range Mini...

Page 18: ...firmware revision number and communications baud rate Values on this screen cannot be modified 5 5 iii e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device...

Page 19: ...function 6 2 Status Screens Run Parameters Displays information about run parameters including date of recording start start date time of recording start start time stop date stop time recording rate...

Page 20: ...RUN displays run parameters screen F2 MEM displays memory status screen F3 TIME displays date and time screen F4 MORE displays ID parameters screen CANCEL returns to main screen OK returns to main sc...

Page 21: ...o function F3 MORE displays run parameters screen F4 EXIT returns to main screen CANCEL returns to main screen OK returns to main screen UP no function DOWN no function 6 6 Statistics Menu Screen Disp...

Page 22: ...returns to Statistics Menu Screen CANCEL returns to Statistics Menu OK returns to Statistics Menu UP no function DOWN no function 6 8 Type Statistics Displays statistics from from the pressure channe...

Page 23: ...nd start time F1 CLEAR gives the option to clear all statistics F2 no function F3 no function F4 EXIT returns to Statistics Menu CANCEL returns to Statistics Menu OK returns to Statistics Menu UP no f...

Page 24: ...PLAY enters Adjust Visibility screen F2 POWER enters Power Modes screen F3 INFO enters Device Information screens F4 EXIT returns to main screen CANCEL returns to main screen OK returns to main screen...

Page 25: ...n Allows the user to change the contrast of the LCD display as well as the channel size F1 CNTRST highlights the contrast parameter configuration tab F2 SIZE highlights and then changes options of the...

Page 26: ...NCEL returns to Device Configuration Menu OK moves to Display Update Mode screen UP once parameter configuration tab is highlighted scrolls through available options DOWN once parameter configuration...

Page 27: ...xternal voltage F1 TYPE highlights and then changes battery type Lithium or Alkaline F3 MORE moves back to Power Modes screen F4 EXIT returns to Device Configuration Screen CANCEL returns to Device Co...

Page 28: ...e Information Screens Maximum Device Range Displays values indicating maximum pressure detectable by the PR2000 6 19 Device Information Screens Device Version Displays device version information F1 VE...

Page 29: ...iguration Menu UP no function DOWN no function 6 21 Calibration Information Screens Calibration Date Displays date of last calibration and due date of next calibration For all Device Information Scree...

Page 30: ...turns to Device Information screens OK returns to Device Information screens UP no function DOWN no function 6 23 Device Reset Screen Hardware Reset Displayed as notification when a hardware reset has...

Page 31: ...rrupted during device operation F1 OK accepts notification and displays main screen F2 no function F3 no function F4 no function CANCEL no function OK accepts notification and displays main screen UP...

Page 32: ...y insert male connector of the IFC200 interface cable into the female receptacle of the data logger WARNING Install driver before connecting a device using a USB for the first time See the Data Logger...

Page 33: ...ld AA batteries from the battery holder and replace with six 6 new AA alkaline batteries as indicated on the holder When re placing the cover make sure that the gasket is still seated in its groove an...

Page 34: ...supersed ed by these terms and conditions and shall not be used to interpret these terms and conditions In the event that Product includes software the software is licensed to Buyer in object code for...

Page 35: ...or corrected during the applicable warranty period shall be in warranty for the greater of the remainder of the applicable original warranty period or ninety 90 days THE FOREGOING STATES THE SOLE AND...

Page 36: ...THAN TWO 2 YEARS AFTER THE CAUSE OF ACTION HAS ACCRUED The foregoing allocation of risk and limitation of liability has been agreed to by the parties and forms the basis of their willingness to enter...

Page 37: ...r alter any notice of the patent copyright or other proprietary rights related to the Software vi sub license sell lend rent or lease any portion of the Software vii copy any portion of the Software v...

Reviews: