background image

HiTemp140X2 Series

Reading Rate 1 reading every second up to 1 reading every 24 hours

Memory 32,767 readings

Memory Wrap 

Around Yes

Start Modes •  Software programmable immediate start

•  Delay start up to 18 months in advance

Stop Modes Manual or Timed (Specific data and time)

Real Time Recording May be used with PC to monitor and record data in real time

Password Protection

An optional password may be programmed into the device to restrict 

access to configuration options. Data may be read out without the 

password.

Readings in Trigger 

Settings Mode 16,383 readings

Trigger Settings

High and Low limits may be set. Once data meets or exceed sets limits, 

the device will record to memory. Bi-level start and stop triggers can 

also be programmed. Users can specify the number of readings to take 

after the device triggers.

 (Triggering on channel #1 only)

Battery Type 3.6V high-temperature lithium battery included user replaceable

Battery  Life   1 year typical (1 minute reading rate at 25 °C/77 °F)
Calibration Digital calibration through software

Calibration Date Automatically recorded within device

Data Format Date and time stamped °C, °F, °R, K,

Time Accuracy  •  1 minute/month at 25 °C (77 °F)

•  Extended Operation: ±20 minutes/month at 140 °C (±450 ppm)

Computer Interface IFC400 or IFC406 USB docking station required; 125,000 baud

Operating System 

Compatibility XP SP3/Vista/Windows 7/Windows 8

MadgeTech Software 

Compatibility

•  MadgeTech Standard Software version 4.2.1.0 or later

•  MadgeTech Secure Software version 4.2.0.0 or later

Operating  

Environment

-40 °C to +140 °C (-40 °F to +284 °F) 

0 %RH to 100 %RH, 0.002 PSIA to 100 PSIA

Note: any X2 logger with an FP probe is only rated to 60 PSIA.

IP Rating IP68

Dimensions (body) 1.89 in x 0.97 in x 0.97 in (48 mm x 24.6 mm x 24.6 mm)

Enclosure Material 316 Stainless Steel

Approvals CE

HiTemp140X2 Series General Specifications

Battery Warning

WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE, FORCE OVER DISCHARGE, 

CRUSH, PENETRATE, OR INCINERATE. BATTERY MAY LEAK OR EXPLODE IF HEATED ABOVE 150 ºC (302 ºF).

Specifications subject to change.

See MadgeTech’s terms and conditions at www.madgetech.com

6

Summary of Contents for HiTemp140X2 Series

Page 1: ...HiTemp140X2 Series To view the full MadgeTech product line visit our website at www madgetech com HiTemp140X2 Series High Temperature Dual Probe Data Logger Series Product User Guide...

Page 2: ...gers Product Overview 2 Additional Features 3 Installation Guide 4 Device Operation 4 Device Maintenance 5 RMA Instructions 5 General Specifications 6 HiTemp140X2 FP Series Product Overview 7 Specific...

Page 3: ...ature a 2 inch rigid fast response transitional diameter probe to measure ambient temperature combined with a second stainless steel bendable or flexible RTD probe option The HiTemp140X2 FP data logge...

Page 4: ...n be programmed to only record based off user configured trigger settings 1 In the Connected devices panel select the intended device to change the settings 2 On the Device tab in the Information grou...

Page 5: ...ameters appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start...

Page 6: ...a minimum of 30 minutes 3 Remove logger from oven and allow to cool to room temp 4 Re assemble the logger with the battery note polarity and endcap RMA Instructions To send a device back in to MadgeTe...

Page 7: ...ing rate at 25 C 77 F Calibration Digital calibration through software Calibration Date Automatically recorded within device Data Format Date and time stamped C F R K Time Accuracy 1 minute month at 2...

Page 8: ...odel offers lightweight flexible RTD probes coated with PFA insulation The FP probe design allows the probe to be easily maneuvered and is ideal for temperature monitoring inside test tubes small vial...

Page 9: ...125 in dia 42 mm x 3 2 mm dia Bendable portion 22 in x 0 062 in dia 559 mm x 1 6 mm dia HiTemp140X2 FP PT 5 Inch Bendable Probe Probe tip 4 8 in x 0 125 in dia with 1 in x 0 188 in dia handle 121 mm x...

Page 10: ...probe sheath at the tip The stainless steel PT probe options provide the ability to retain shape when bent into position and the sharp probe tip allows for easy insertion The stainless steel PT probes...

Page 11: ...a 42 mm x 3 2 mm dia Bendable portion 22 in x 0 062 in dia 559 mm x 1 6 mm dia HiTemp140X2 TD PT 5 Inch Bendable Probe Probe tip 4 8 in x 0 125 in dia with 1 in x 0 188 in dia handle 121 mm x 3 2 mm d...

Page 12: ...are click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the IFC400 or IFC406...

Reviews: