HiTemp140X2 Series

Installation Guide

Installing the Interface cable

- IFC400 or IFC406 

Refer to the “Quick Start Guide” included in the package.

Installing the software

The Software can be downloaded from the MadgeTech website at the following link: 

www.madgetech.com/software-download

. Follow the instructions provided in the 

Installation Wizard to install the MadgeTech Software. 

Device Operation

Connecting and Starting the data logger

- Once the software is installed and running, plug the interface cable into the docking 

station.

- Connect the USB end of the interface cable into an open USB port on the computer.
- Place the data logger into the docking station.
- The data logger will automatically appear under 

Connected Devices

 within the software.

- For most applications, select 

Custom Start

 from the menu bar and choose the desired start 

method, reading rate and other parameters appropriate for the data logging application 
and click 

Start

. (

Quick Start

 applies the most recent custom start options, 

Batch Start 

is used 

for managing multiple loggers at once, 

Real Time Start 

stores the dataset as it records while 

connected to the logger.

)

- The status of the device will change to 

Running

Waiting to Start

 or 

Waiting to Manual 

Start

, depending upon your start method.

- Disconnect the data logger from the docking station and place it in the environment to 

measure.

Note: The device will stop recording data when the end of memory is reached or the device is stopped, unless user selectable 
memory wrap is enabled. At this point the device cannot be restarted until it has been re-armed by the computer.

Downloading data from a data logger

- Place the logger into the docking station.
- Highlight the data logger in the 

Connected Devices

 list. Click 

Stop

 on the menu bar.

- Once the data logger is stopped, with the logger highlighted, click 

Download

. You will 

be prompted to name your report.

- Downloading will offload and save all the recorded data to the PC.

4

Summary of Contents for HiTemp140X2 Series

Page 1: ...HiTemp140X2 Series To view the full MadgeTech product line visit our website at www madgetech com HiTemp140X2 Series High Temperature Dual Probe Data Logger Series Product User Guide...

Page 2: ...gers Product Overview 2 Additional Features 3 Installation Guide 4 Device Operation 4 Device Maintenance 5 RMA Instructions 5 General Specifications 6 HiTemp140X2 FP Series Product Overview 7 Specific...

Page 3: ...ature a 2 inch rigid fast response transitional diameter probe to measure ambient temperature combined with a second stainless steel bendable or flexible RTD probe option The HiTemp140X2 FP data logge...

Page 4: ...n be programmed to only record based off user configured trigger settings 1 In the Connected devices panel select the intended device to change the settings 2 On the Device tab in the Information grou...

Page 5: ...ameters appropriate for the data logging application and click Start Quick Start applies the most recent custom start options Batch Start is used for managing multiple loggers at once Real Time Start...

Page 6: ...a minimum of 30 minutes 3 Remove logger from oven and allow to cool to room temp 4 Re assemble the logger with the battery note polarity and endcap RMA Instructions To send a device back in to MadgeTe...

Page 7: ...ing rate at 25 C 77 F Calibration Digital calibration through software Calibration Date Automatically recorded within device Data Format Date and time stamped C F R K Time Accuracy 1 minute month at 2...

Page 8: ...odel offers lightweight flexible RTD probes coated with PFA insulation The FP probe design allows the probe to be easily maneuvered and is ideal for temperature monitoring inside test tubes small vial...

Page 9: ...125 in dia 42 mm x 3 2 mm dia Bendable portion 22 in x 0 062 in dia 559 mm x 1 6 mm dia HiTemp140X2 FP PT 5 Inch Bendable Probe Probe tip 4 8 in x 0 125 in dia with 1 in x 0 188 in dia handle 121 mm x...

Page 10: ...probe sheath at the tip The stainless steel PT probe options provide the ability to retain shape when bent into position and the sharp probe tip allows for easy insertion The stainless steel PT probes...

Page 11: ...a 42 mm x 3 2 mm dia Bendable portion 22 in x 0 062 in dia 559 mm x 1 6 mm dia HiTemp140X2 TD PT 5 Inch Bendable Probe Probe tip 4 8 in x 0 125 in dia with 1 in x 0 188 in dia handle 121 mm x 3 2 mm d...

Page 12: ...are click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the IFC400 or IFC406...

Reviews: