15
CrossFire 8650/8651 UEM Guide to Operation, DOC-7090 v. 1.0
3. Console Configuration
Configuration Overview
Execute the following general steps to configure a CrossFire 8650 or 8651 UEM:
•
Determine which VLANs the HSTR ports should connect.
•
Determine which VLAN, if any, should be untagged.
•
Configure the 802.1Q VLAN ID for all BRFs that should be tagged.
•
Make sure that each 802.1Q VLAN ID matches that of the HSTR equipment
on the other end.
•
Assign CRFs to the HSTR port, thereby creating one virtual port in each
VLAN. You can create new CRFs to make sure that the CRFs do not have
conflicting ring numbers, as discussed in "Ring Number Restriction"
on
•
Configure the HSTR port, in particular the operation mode.
•
Configure the virtual ports, in particular the tagging mode. The relevant
configuration menus are described in the port configuration sections.
865x.Book Page 15 Wednesday, October 6, 1999 2:31 PM