CrossFire 8650/8651 UEM Guide to Operation, DOC-7090 v. 1.0

2. Installation

LEDs

There are six LEDs on the front panel of a CrossFire 8650 or 8651 UEM. During 
normal operation, the two LEDs on the left side of the front panel indicate the 
module status:

The two LEDs on the right of every port indicate the port status:

LED

Position

State

Meaning

DIAG (green)

Top

On 

Diagnostics are in process.

Off

No diagnostics are in process.

ERR (yellow)

Bottom

On

A module failure has occurred.

Off

The module is working correctly.

Table 1.  LEDs at the Left on the Front Panel

LED

Position

State

Meaning

LINK (green)

Top

On

The port has linked and is 
inserted.

Flashing

The port is disabled.

Off

The port is not inserted.

ACTIVITY 
(green)

Bottom

Flashing

The port is receiving or 
transmitting LLC frames.
Note that the ACTIVITY LED 
does not flash for MAC frames.

Off

There is no LLC traffic on the 
port

Table 2.  LEDs at the Right of Every Port

865x.Book  Page 9  Wednesday, October 6, 1999  2:31 PM

Summary of Contents for CrossFire 8650

Page 1: ...DOC 7090 1 0 CrossFireTM 8650 8651 High Speed Token Ring UEM Guide to Operation 865x Book Page 1 Wednesday October 6 1999 2 31 PM...

Page 2: ...865x Book Page 2 Wednesday October 6 1999 2 31 PM...

Page 3: ...CrossFire TM 8650 8651 High Speed Token Ring UEM Guide to Operation 865x Book Page i Wednesday October 6 1999 2 31 PM...

Page 4: ...with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated...

Page 5: ...00 3 3 EN 55022 EN 60950 EN 60825 1 following the provisions of 89 336 EEC Directive and 73 23 EEC Directive Modifications If the device is changed or modified without the express approval of Madge th...

Page 6: ...iv CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 865x Book Page iv Wednesday October 6 1999 2 31 PM...

Page 7: ...le Configuration 11 Introduction 12 Ports Port Groups and VLANs 12 HSTR Virtual Ports and VLAN Tagging 12 Virtual Port Restriction 13 Ring Number Restriction 13 General Guidelines 14 Navigating the Me...

Page 8: ...Figure 3 Inserting the Module 5 List of Tables Table 1 LEDs at the Left on the Front Panel 9 Table 2 LEDs at the Right of Every Port 9 Table 3 HSTR Port Configuration Status Values 16 Table 4 Virtual...

Page 9: ...one the information in this guide applies to both Chapter 2 Installation lists the package contents describes the front panel and explains how to install connect configure and test the modules Chapter...

Page 10: ...viii CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 865x Book Page viii Wednesday October 6 1999 2 31 PM...

Page 11: ...ssFire 8600 and CrossFire 8605 Switches Figure 1 CrossFire 8650 High Speed Token Ring UEM The CrossFire 8650 and 8651 UEMs conform to the IEEE 802 5t standard for 100 Mbps High Speed Token Ring and im...

Page 12: ...2 CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 1 Introduction 865x Book Page 2 Wednesday October 6 1999 2 31 PM...

Page 13: ...aining the Token Ring switch program and the Switch Manager for Windows and HP OpenView for Windows as well as user documentation in PDF format One CrossFire 8650 8651 High Speed Token Ring UEM Guide...

Page 14: ...on the switch 8 Download the software for the module See section Software Installation on page 6 for detailed instructions 9 If you plan to use the graphical switch manager application install it now...

Page 15: ...d into the connector at the back of the slot See Figure 3 When the module is fully seated the module faceplate will be flush with the front of the base switch Figure 3 Inserting the Module 5 Secure th...

Page 16: ...the software image 2 Copy the software image file to a directory on the TFTP server 3 On the main menu in the console select Download Upload to display the Download Upload menu 4 Select TFTP Download...

Page 17: ...ule find the software image file The file name is of the form 865Xabc BIN where abc is the version number of the software For example 865X400 BIN is version 4 0 0 of the software image 2 From the main...

Page 18: ...guration The UTP module also supports IBM type 1 STP copper cables 150 Ohm which have a maximum length of 100 m 328 feet To use an STP cable then balluns with an RJ 45 connector are required CrossFire...

Page 19: ...process Off No diagnostics are in process ERR yellow Bottom On A module failure has occurred Off The module is working correctly Table 1 LEDs at the Left on the Front Panel LED Position State Meaning...

Page 20: ...Ms From the switch console via Telnet or directly with a VT100 terminal emulator on the RS 232 port Through the SNMP based graphical management application OC 8840 Chapter 3 Console Configuration desc...

Page 21: ...n can also be modified from a remote VT100 console via a Telnet session Connecting a network management console is explained in the manual supplied with the CrossFire 8600 and 8605 Switches The follow...

Page 22: ...LAN in which they origin Frames must be routed to move between VLANs A VLAN consists of a number of port groups called Concentrator Relay Function CRFs A CRF is conceptually equal to a ring If a VLAN...

Page 23: ...18 Note that an HSTR port with a single untagged virtual port is functionally equivalent to an ordinary Token Ring port This is also the default configuration with the virtual port in trcrf default V...

Page 24: ...To refresh the console panel at any time press CTRL L If you are administering switches in a stack many of the console screens will prompt for a box number Enter the number of the box you want to adm...

Page 25: ...ake sure that each 802 1Q VLAN ID matches that of the HSTR equipment on the other end Assign CRFs to the HSTR port thereby creating one virtual port in each VLAN You can create new CRFs to make sure t...

Page 26: ...led Determines whether the port is enabled Yes or No When the port is disabled the LINK LED will blink This is also the case if the port has been auto disabled see Cfg Loss Threshold and Cfg Loss Samp...

Page 27: ...tion loss in case of lobe test failure heartbeat failure address change or other MAC protocol error Default 8 Cfg Loss Sampling Interval Sets the sampling interval in which the Cfg Loss threshold must...

Page 28: ...virtual port must be selected The following menu appears Enabled Sets the administrative state of the virtual port possible values are Yes and No Default Yes Status Display only Shows the current stat...

Page 29: ...are used in explorer RIF expansion Also shown is the actual MTU for the BRF If Use BRF is selected the BRF value will be used Otherwise the lowest of the BRF MTU and port MTU values will be used Thus...

Page 30: ...th ends Preferably the VLAN which is expected to have the largest amount of traffic should be untagged since VLAN tagging does impose a small overhead Default Untagged first virtual port Default Tagge...

Page 31: ...ing Time Sets the aging time for addresses learned on an HSTR port When there has been no activity on an address for the specified period of time it is deleted from the address tables Range 1 to 9999...

Page 32: ...22 CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 3 Console Configuration 865x Book Page 22 Wednesday October 6 1999 2 31 PM...

Page 33: ...A wide range of statistics is available for the CrossFire 8650 and 8651 UEMs The following topics are discussed in this chapter Statistics Menu Port Status Port Statistics General Statistics Virtual P...

Page 34: ...Guide to Operation For general information about these commands refer to that manual Some commands however display additional information that is specific to the CrossFire 8650 and 8651 UEMs Port Stat...

Page 35: ...displayed Port The HSTR port for which the virtual port is defined Range 21 22 25 or 26 TrCRF The name of the CRF in which the virtual port is defined TrBRF The name of the BRF in which the virtual po...

Page 36: ...R port and is shared by all the virtual ports on that port The actual bandwidth on a particular virtual port thus depends on the amount of traffic on other virtual ports Oper Mode The operation mode i...

Page 37: ...atistics When Port Statistics is selected and the port number of an HSTR port is entered the following menu appears The available information is discussed in General Statistics 802 5 Statistics and Vi...

Page 38: ...d every 5 seconds Frame and Byte Counters The following frame and byte counters are defined Received Frames received from HSTR but not necessarily forwarded Forwarded Frames received from HSTR and for...

Page 39: ...AN frame tag is removed before a frame is forwarded NSR Frames Number of Non Source Routed frames SRF Frames Number of Specifically Routed Frames STE Frames Number of Spanning Tree Explorers ARE Frame...

Page 40: ...Frames When Discarded Frames is chosen on the general statistics display the following screen appears Wire Fault The port was closed due to a wire fault perhaps because the cable was removed Lobe Test...

Page 41: ...he 802 1Q VLAN ID and virtual port tagging mode is set to the same value on both sides of the connection Invalid Route The frame had an invalid Route Information Field RIF Possible reasons are because...

Page 42: ...ured maximum hop count limit if more hops were added The frame therefore was forwarded only to the other ports in the same CRF as the receiving virtual port Filtered By Address Filter A frame was disc...

Page 43: ...ave been permanent because the spanning tree protocol detected multiple parallel paths or transient during network topology changes Filtered By DSAP Filter A frame was discarded because of a protocol...

Page 44: ...virtual port Refer to Chapter 3 section Virtual Port Configuration on page 18 for details Frames Forwarded The number of LLC frames received and forwarded on this virtual port Frames Transmitted The...

Page 45: ...ected from the HSTR Port Statistics menu information about the Token Ring MAC layer protocol is displayed The information on this menu is similar to that for ordinary Token Ring ports Refer to the Cro...

Page 46: ...36 CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 4 Statistics 865x Book Page 36 Wednesday October 6 1999 2 31 PM...

Page 47: ...any traffic through the switch will be disrupted Issue the sys stat command and capture the result as well as all relevant switch configuration displays into a file Print the file Dump the switch conf...

Page 48: ...4 1753 661000 Fax 44 1753 661011 Asia Pacific Suit 4B 15 Orion Road Lane Cove NSW 2066 Australia Email asiatech madge com Technical support 61 2 9936 1700 Tel 61 2 9936 1700 Fax 61 2 9936 1799 America...

Page 49: ...ion Address DSAP Destination SAP DTR Dedicated Token Ring ECO Engineering Check Order FC Frame Control FCS Frame Check Sequence FDX Full Duplex HDX Half Duplex HSTR High Speed Token Ring IP Internet P...

Page 50: ...e Routing SRB Source Route Bridging SRF Specifically Routed Frame SRS Source Route Switching SRT Source Route Transparent SSAP Source SAP STE Spanning Tree Explorer TCI Tag Control Information TFTP Tr...

Page 51: ...ns 13 I installation 3 cabling 8 physical 4 procedure for 3 software 6 introduction 1 L LEDs 9 M menu navigation 14 message log 24 N navigating in the menus 14 navigating the menus 14 P package conten...

Page 52: ...index 2 CrossFire 8650 8651 UEM Guide to Operation DOC 7090 v 1 0 index 865x Book Page 2 Wednesday October 6 1999 2 31 PM...

Page 53: ...865x Book Page 1 Wednesday October 6 1999 2 31 PM...

Page 54: ...B 15 Orion Road Lane Cove NSW 2066 Australia Email asiatech madge com Technical support 61 2 9936 1700 Tel 61 2 9936 1700 Fax 61 2 9936 1799 Europe Middle East Africa Wexham Springs Framewood Road Wex...

Reviews: