A B
NOTE 1: Never pull the hose to move the unit. This could damage hose and/or pump inlet.
NOTE 2: Water source must provide a minimum of 5 gallons per minute at 20 p.s.i. Inlet hose can
connect to the water main with Max. inlet pressure 1MPa.
NOTE 3: Use cold water only and water’s temperature shall not exceed 50
℃
.
1)
Turn water source on.
2)
Turn knob clockwise and anticlockwise in order to get pencil jet and 0~40°fan jet.
EXPLANATION:
0° Nozzle- Used for a pinpoint stream. This nozzle stream is very powerful and covers a very
small area of cleaning. This nozzle should only be used on surfaces that can this high pressure
such as metal or concrete.
15° and 25°Nozzle-Used for less powerful steam which can cover a wider area. This nozzle is
also very powerful and should only be used on surfaces that can withstand this high pressure.
40°Nozzle-Used for the least powerful stream and covers a wide area of cleaning. This
nozzle should be used for most general cleaning jobs.
O
PERATION
:
NOTE: Do not let hoses come in contact with the HOT engine muffler during or immediately after
use, as this will destroy the hose.
1) Press the trigger safety lock, and then you can press the trigger
2) Start engine according to the engine owner’s manual.
3) Press the trigger of high-pressure gun to make sure water flowing out. Be careful when
press the trigger gun, it has recoil force and the sudden torque. Release the trigger of
high-pressure gun can stop the water flowing out.
In emergency condition: Turn engine off.
49
Summary of Contents for POWER TOOLS AGW-180E
Page 2: ......