17
6.2.2 Run the unit for several minutes without load to cool down the generator set.
6.2.3 Set the ignition switch to OFF position(Figure 35)
6.2.4 Set the fuel switch to OFF position (Figure 36)
WARNING
Don’t touch the heating components before th
e unit cools down
after stopping the engine to avoid burns.
CAUTION
Fuel storage in unit which is not to be used for long time will
cause it difficult to start the engine. Drain the fuel for long-time storage of
the unit.
7 Maintenance
7.1 Maintenance Schedule:
The Unit should be serviced according to the following
Maintenance Schedule:
Perio
d
Item
Each
Time
20 Hrs or
1st Month
50Hrs or Every
3 Month
100Hrs or
every 6
Month
300Hrs or
every one
year
Check engine oil
Check
Replace engine oil
Replace
Replace
Check air cleaner
Check
Wash air cleaner
Clean
Oil filter cover
Clean
Battery electrolyte
level
Check
Spark plug
Clean