gu_gas_tracker2_v_2_15_en
10 / 35
The resonator tank leans on the customer meter box. A supporting leg is integrated into the
handle of the tank. The leg is adjustable by a knob to accommodate the height of the box.
A retaining strap is provided for high installation.
4.2.3.
Procedure for putting the transmitter into service :
In addition to the following instructions, please follow the procedures applicable at your local
gas network operator.
transmitter allows the acoustic signal to be
1.
Remove the meter
2.
Connect the resonator tank to the inlet valve, the purge valve must be open. Use the supporting
leg and the copper fittings if required.
3.
OPEN the GAS by SLOWLY OPENING the CUSTOMER TAP so as not to damage the inner
membrane.
4.
Leave the drain valve open for 5 seconds and close.
5.
Check the connection for leaks
6.
Connect the power supply
7.
Press the ON button (green)
The signal then propagates into the gas and vibrates the pipe.
Check the battery level, if it is
orange
or
red
then ,
o
Use the external connection cord (connection to vehicle battery or cigarette lighter
adapter)