Tabella 2 - Table 2 - Tableau 2

 

-

 

Tabla 2

Bobine e connettori  -  Coils and connectors  -  Bobines et connecteurs -  Bobinas y conectores

Modello/Ø

Model/Ø

Modèle/Ø

Modelo/Ø

Voltaggio

Voltage

Voltage

Voltaje

Codice bobina

Coil code

Code bobine

Códice bobina

Timbratura bobina

Coil stamping

Timbrage bobine

Timbre bobina

Codice connettore

Connector code

Code conecteur

Códice conector

Potenza assorbita

Absorbed power

Puissance absorbée

Potencia absorbida

M1

4/RM N.C.  - M1

4/RMC N.C

Rp DN 1

5 - Rp DN 20 - Rp DN 25

 

(P

. max 0,5 bar)

M1

6/RMO N.C.

Rp DN 1

5 - Rp DN 20 - Rp DN 25

(P

. max 0,5 -6 bar)

12 Vdc

BO-0030

BO-0030

12 V DC R

CN-0010

8 VA

12 V/50 Hz

BO-0030

BO-0030

12 V DC R

CN-0050

8 VA

24 Vdc

BO-0040

BO-0040

24 V DC R

CN-0010

8 VA

24 V/50 Hz

BO-0040

BO-0040

24 V DC R

CN-0050

8 VA

110 V/50-60 Hz

BO-0075

BO-0075

110 V RAC

CN-0045

8 VA

230 V/50-60 Hz

BO-0050

BO-0050

220 V RAC

CN-0045

9 VA

Tipo connettore / Connector type / Type de connecteur / Tipo de conector
CN-0010

  = Normale / Normal / Normal / Normal

CN-0045

 (230 Vac, 110 Vac) = Raddrizzatore / Rectifier / Reddresseur / Rectificador

CN-0050

 (24 Vac, 12 Vac) = Raddrizzatore / Rectifier / Reddresseur / Rectificador

Summary of Contents for M14/RM N.C

Page 1: ...ADE IN ITALY IT EN FR ES M14 RM N C M14 RMC N C M16 RMO N C 0497 0051 Omologazione CE secondo EN 161 conforme Regolamento UE 2016 426 Direttiva PED 2014 68 UE EC approval according to EN 161 compliant...

Page 2: ...sins Dise os 43 Dimensioni tabella 1 45 Dimensions table 1 Dimensions tableau 1 Dimensiones tabla 1 Bobine e connettori di ricambio tabella 2 46 Spare coils and connectors table 2 Bobines et connecteu...

Page 3: ...CRIPTION Normally closed manual reset solenoid valves for gas suitable to shut off gas both to signal danger sent by gas detectors methane LPG carbon monoxide and similar or safety thermostats and in...

Page 4: ...uld compromise correct device operation The manufacturer is not liable for malfunctions caused by unauthorised tampering or use of non original parts 1 5 IMPROPER USE The product must only be used for...

Page 5: ...p Threaded connections DN 15 DN 20 DN 25 according to EN 10226 NPT Threaded connections request feasibility Filter element 1 mm wire mesh only for M14 RM N C M14 RMC N C In compliance with Regulation...

Page 6: ...ng out any electrical wiring operations make sure that the mains voltage matches the supply voltage indicated on the product label Cut off power prior to proceeding with wiring According to the plant...

Page 7: ...e individual devices In any case following installation check the tightness of the plant Wiring cannot have cables connected directly to the coil ALWAYS and ONLY use the connector identified by the ma...

Page 8: ...TION 1 M14 RM N C Manual reset solenoid valve 2 SM jerk ON OFF valve 3 FM gas filter 4 OPSO series MVB 1 MAX shut off valve 5 RG 2M pressure regulator 6 MVSP 1 relief valve 7 Pressure gauge and relati...

Page 9: ...place Or seal it in that position 5 0 FIRST START UP Before start up make sure that all of the instructions on the rating plate including the direction of flow are observed After having gradually pres...

Page 10: ...the coil 12 needs to be changed following an electrical failure we recommend changing the connector 1 as well The coil and or connector replacement operations need to be carried out taking care to en...

Page 11: ...d condensation At the end of its service life the product is to be disposed of separately from other waste WEEE directive 2012 19 EU and in compliance with the legislation in force in the country wher...

Page 12: ...equency if Vac followed by electrical absorption 20 60 C Temperature range within which product operation is guaranteed Conformity with Regulation EU 2016 426 followed by Notified Body No if it is pre...

Page 13: ...43 IT EN FR ES fig 2 M16 RMO N C DN 15 DN 20 DN 25 fig 1 M14 RM N C M14 RMC N C DN 15 DN 20 DN 25...

Page 14: ...screw 14 Connector centre screw 15 Filter element fig 1 et 2 1 Connecteur lectrique 2 Vis de fixation du couvercle 3 Joint torique d tanch it du couvercle 4 Rondelle d tanch it 5 Corps de vanne 6 Pivo...

Page 15: ...M N C Rp DN 15 Rp DN 20 75 163 74 52 111 M14 RMC N C Rp DN 25 compact 75 163 74 52 111 M14 RM N C Rp DN 25 90 172 74 52 120 M16 RMO N C Rp DN 15 Rp DN 20 66 132 37 45 87 M16 RMO N C Rp DN 25 82 142 44...

Page 16: ...M14 RMC N C Rp DN 15 Rp DN 20 Rp DN 25 P max 0 5 bar M16 RMO N C Rp DN 15 Rp DN 20 Rp DN 25 P max 0 5 6 bar 12 Vdc BO 0030 BO 0030 12 V DC R CN 0010 8 VA 12 V 50 Hz BO 0030 BO 0030 12 V DC R CN 0050 8...

Page 17: ...arge calcul avec P1 50 mbar Diagrama de p rdidas de carga calculado con P1 50 mbar dv densit relativa all aria dv density relative to the air dv densit relative l air dv densidad relativa del aire 1 m...

Page 18: ...0442 23289 Fax 39 0442 27821 http www madas it e mail info madas it Ci riserviamo qualsiasi modifica tecnica e costruttiva We reserve the right to make any technical or constructive changes Nous nous...