26
IT
EN
FR
ES
9.0 - RATING PLATE DATA
The rating plate data (see example provided here) includes the following:
• Manufacturer’s name/logo and address (possible distributor name/logo)
• Mod.:
= device name/model followed
by the connection diameter
• CE-51CM4100 = certification pin number
• Cl. A
= Seal strength in counterflow at 150 mbar in accordance with EN 161
• Gr. 2
= Mechanical resistance group 2 in accordance with EN 161
• EN 161
= Product reference regulation
• P.max
= Maximum pressure at which product operation is guaranteed
• IP....
= Protection rating
• 230V....
= Power supply voltage, frequency (if Vac), followed by electrical absorption
Example of electrical absorption indication: 89/25 VA indicates 89 VA at start, 25 VA at steady state
• TS
= Temperature range within which product operation is guaranteed
•
= Conformity with Regulation (EU) 2016/426 followed by Notified Body No.
• year
= Year of manufacture
• Lot
= Product serial number (see explanation below)
• U1804
= Lot issued in year 2018 in the 4th week
• 2185
= progressive job order number for the indicated year
• 00001
= progressive number referring to the quantity of the lot