MAINTENANCE
FILTER BASKET AND FOG CAPTURE CONTAINER
WIPER / ROLLER
This should be removed and cleaned as part of your periodic servicing but for most of the time the wash cycle will keep it
clean and clear. Inspect wiper blade during periodic inspection for wear or disfiguration.
The wiper chute is removed by lifting out. To replace, lift back in and position the two locating holes in the chute with the
two locating studs on the tank sidewall.
NOTE: Keep solids especially coffee grinds, onion peel, bones, utensils and plastics out of the unit. This is important to
ensure the efficient operation of the extraction process and prevent any build-up of rubbish in the chute area.
•
To assist and limit problems of internal solids build up, before pre-wash rising, wipe any dairy waste off dishes /utensils
into rubbish.
•
We recommend permanent sink solids filters be used in addition to the MACTRAP filter basket.
•
Use hot water for washing
6
•
Open door and remove filter basket
•
Empty contents to waste bin
•
Clean and replace
•
Close door
Remove waste fat, oil and grease collection container
(old milk bottles are ideal to use) and put in refuse.
Wiper chute cleaning nozzle
FOG collection roller
Wiper blade affixed to collection chute
MO
NT
HL
Y
R
EG
U
LA
R