![MacroAir Technologies AirVolution 550 Installation Manual Download Page 38](http://html1.mh-extra.com/html/macroair-technologies/airvolution-550/airvolution-550_installation-manual_3272376038.webp)
© 2015 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com 36
Rev. Date 090415
Components:
A - Safety Cable
B - Power Cable or Wires
C - Remote Cable
D - Safety Cable Attachment Point
(Minimum load rating 1,000 lbs)
E - AC Power Source
F - Touchpad Remote
G - Mount
H - Fuse Disconnect Switch
(add-on)
3.4.1A:
For Glulam or wood beam installation, drill a hole through the beam above the center line
and route the safety cable in a loop and attach the cable to itself with the provided cable clamps.
Make sure that there is little to no slack in the safety cable. Avoid sharp edges.
3.4.1B:
For I-beam installation, beam clamps can be used with eye bolts. Attach the beam clamps
on both sides of the beam and route the safety cable through the eye bolts. Attach the cable to
itself using the provided cable clamps and make sure that there is no slack. Avoid sharp edges.
3.4.2:
Run the remote cable to the remote location. The cable can be run in conduit or open if
desired as the cable is low voltage and shielded. To attach to the touchpad remote, simply plug
the end of the remote cable into the RJ45 jack on the touchpad remote.
3.4.3:
Connect to power in compliance with local and state codes. This device may require a
disconnect that is outside of the swept area of the airfoils to comply with OSHA (not provided).
Refer to the above illustration for the Final Results.
3.4 Safety Cable & Electrical Installation
A
B
C
D
G
E
F
H