12
© 2014 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com Rev. Date 111714
MOUNTING
ASSEMBLY - POLE
• Cut and mount bracketing: Cut and assemble UniStrut or equivalent bracketing (not included). Use the mount assembly as a template
for length and hole spacing. Securely attach the brackets to the pole at the desired height. Be sure that all strap bolts are firmly
tightened and that the vertical spacing is correct.
• Attach the fan to the bracketing: Insert 1/2” bolts with 1 washer each into the brackets. Slide the mount assembly over the bolts and
attach using nylon lock nuts and flat washers.